MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/mao.0000000000000954

Медицинская библиотека · Otology & neurotology : official publication of the American Otological Society, American Neurotology Society [and] European Academy of Otology and Neurotology · 2016

Dickkopf-related Protein 3 as a Sensitive and Specific Marker for Cerebrospinal Fluid Leaks.

Michaelides Elias M, Kuang Heide, Pieribone Vincent A

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

HYPOTHESIS: Cerebrospinal fluid (CSF) can be identified by using an enzyme-linked immunosorbent assay (ELISA) for Dickkopf-related protein 3 (DKK3).

BACKGROUND

Cerebrospinal fluid leakage from the subarachnoid space is a potentially alarming condition that, left unrepaired, may result in increased risk of meningitis and encephalitis. Current biochemical methods of CSF leak detection involve using beta-2-transferrin-based or beta trace protein-based assays, both of which, at present, have limitations that hinder practical clinical application. This study presents the immunological detection of the CSF-enriched protein DKK3 as a method for detection of a CSF leak.

METHODS

Antibodies against DKK3 were generated in rabbits and goats immunized with recombinant human DKK3. Varying dilutions and combinations of human CSF and serum were tested on immunoblots and sandwich ELISA using antibodies to DKK3.

RESULTS

ELISA data show that there is a negligible amount of detectable DKK3 in serum samples compared with CSF samples. Inclusion of sera (up to 30%) in a sample containing CSF failed to produce a positive signal, whereas concentrations of CSF as low as 1% produced a positive signal. The minimum concentration required for reliable CSF detection in a sandwich ELISA was determined to be 0.5  μl.

CONCLUSION

ELISA sandwich assays for DKK3 can reliably detect the presence of as little as 0.5 μl of human CSF, even in the presence of excessive serum. This study provides quantitative evidence of the utility of DKK3 immunoreactivity as an assay for the presence of CSF in samples that contain contaminating sera. The robustness of this assay has allowed for the development of a rapid, point of care test for the detection of CSF in clinical and surgical setting.

Для цитирования: Michaelides Elias M, Kuang Heide, Pieribone Vincent A. Dickkopf-related Protein 3 as a Sensitive and Specific Marker for Cerebrospinal Fluid Leaks.. Otology & neurotology : official publication of the American Otological Society, American Neurotology Society [and] European Academy of Otology and Neurotology. 2016. DOI: 10.1097/mao.0000000000000954.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.