MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1136/jnnp-2015-310853

Медицинская библиотека · Journal of neurology, neurosurgery, and psychiatry · 2015

Management of spontaneous intracranial hypotension - Transorbital ultrasound as discriminator.

Fichtner Jens, Ulrich Christian T, Fung Christian, Knüppel Christin, Veitweber Martina, Jilch Astrid, Schucht Philippe, Ertl Michael, Schömig Beate, Gralla Jan, Z'Graggen Werner J, Bernasconi Corrado, Mattle Heinrich P, Schlachetzki Felix, Raabe Andreas, Beck Jürgen

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVE

Spontaneous intracranial hypotension (SIH) is most commonly caused by cerebrospinal fluid (CSF) leakage. Therefore, we hypothesised that patients with orthostatic headache (OH) would show decreased optic nerve sheath diameter (ONSD) during changes from supine to upright position.

METHODS

Transorbital B-mode ultrasound was performed employing a high-frequency transducer for ONSD measurements in the supine and upright positions. Absolute values and changes of ONSD from supine to upright were assessed. Ultrasound was performed in 39 SIH patients, 18 with OH and 21 without OH, and in 39 age-matched control subjects. The control group comprised 20 patients admitted for back surgery without headache or any orthostatic symptoms, and 19 healthy controls.

RESULTS

In supine position, mean ONSD (±SD) was similar in patients with (5.38±0.91 mm) or without OH (5.48±0.89 mm; p=0.921). However, in upright position, mean ONSD was different between patients with (4.84±0.99 mm) and without OH (5.53±0.99 mm; p=0.044). Furthermore, the change in ONSD from supine to upright position was significantly greater in SIH patients with OH (-0.53±0.34 mm) than in SIH patients without OH (0.05±0.41 mm; p≤0.001) or in control subjects (0.01±0.38 mm; p≤0.001; area under the curve: 0.874 in receiver operating characteristics analysis).

CONCLUSIONS

Symptomatic patients with SIH showed a significant decrease of ONSD, as assessed by ultrasound, when changing from the supine to the upright position. Ultrasound assessment of the ONSD in two positions may be a novel, non-invasive tool for the diagnosis and follow-up of SIH and for elucidating the pathophysiology of SIH.

Для цитирования: Fichtner Jens, Ulrich Christian T, Fung Christian, Knüppel Christin, Veitweber Martina, Jilch Astrid, Schucht Philippe, Ertl Michael, Schömig Beate, Gralla Jan, Z'Graggen Werner J, Bernasconi Corrado, Mattle Heinrich P, Schlachetzki Felix, Raabe Andreas, Beck Jürgen. Management of spontaneous intracranial hypotension - Transorbital ultrasound as discriminator.. Journal of neurology, neurosurgery, and psychiatry. 2015. DOI: 10.1136/jnnp-2015-310853.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.