RetCam imaging for retinopathy of prematurity screening.

Wu Carolyn, Petersen Robert A, VanderVeen Deborah K

СтатьяМногоцентровое исследованиеПеревод пока не подготовлен

Аннотация

PURPOSE: Indirect ophthalmoscopy is the gold standard for retinopathy of prematurity (ROP) screening. Screening for ROP with digital imaging has been proposed as a possible alternative. Our goal was to evaluate the longitudinal clinical outcomes of employing digital imaging to detect high-risk ROP.

METHODS

Serial RetCam imaging and indirect ophthalmoscopy were performed on 43 premature infants. A masked reader evaluated the images and made management recommendations that were compared with indirect ophthalmoscopy results. Successful screening was determined by correctly identifying progression to prethreshold or threshold disease with referral for indirect ophthalmoscopy. Unsuccessful screening was determined by failure to identify prethreshold or threshold disease, inaccurately detecting prethreshold or threshold disease, or inability to evaluate for ROP.

RESULTS

No cases of prethreshold or threshold disease were missed by the reader. The reader overestimated prethreshold or threshold disease in 5% of cases. Initial screening in 21% of cases could not be evaluated for ROP secondary to poor image quality. Digital photography had a sensitivity of 100% and specificity of 97.5% in detecting prethreshold and threshold ROP. Positive-predictive value of digital photography was 67% and negative-predictive value was 100%.

CONCLUSIONS

Screening and management of ROP using RetCam imaging did not fail to detect prethreshold or threshold disease when images could be obtained. Ophthalmologic examinations were needed in 20% of cases that did not reach threshold or prethreshold disease because of poor image quality or overestimation of ROP. RetCam screening may safely reduce the overall number of indirect ophthalmologic examinations required.

Для цитирования: Wu Carolyn, Petersen Robert A, VanderVeen Deborah K. RetCam imaging for retinopathy of prematurity screening.. Journal of AAPOS : the official publication of the American Association for Pediatric Ophthalmology and Strabismus. 2006. DOI: 10.1016/j.jaapos.2005.11.019.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.