MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/s0034-5687(00)00196-1

Медицинская библиотека · Respiration physiology · 2001

Effect of acute metabolic acid/base shifts on the human airway calibre.

Brijker F, van den Elshout F J, Heijdra Y F, Bosch F H, Folgering H T

Клиническое исследованиеКонтролируемое клиническое исследованиеСтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

Acute metabolic alkalosis (NaHCO(3)), acidosis (NH(4)Cl), and placebo (NaCl) were induced in 15 healthy volunteers (12 females, median age 34 (range 24-56) years) in a double blind, placebo controlled study to evaluate the presence of the effects on airway calibre. Acid-base shifts were determined by capillary blood gas sampling. Measurements were performed at the maximal acid-base shift, 90 min after intervention. Airway resistance (R(aw)) and specific airway conductance (sG(aw)), were evaluated, as primary variables, pre and post intervention. Secondary variables, including bronchial responsiveness to histamine, maximal respiratory mouth pressures and grip strength, were evaluated post intervention. In alkalosis, base excess (BE) increased from -0.3 (-3.0-1.9) to 3.0 (1.0-4.8) mmol/l and pH increased from 7.41 (7.37-7.43) to 7.44 (7.39-7.47) (both P<0.01), accompanied by an increase in Pa(CO(2)): 4.7 (4.0-5.7) to 5.0 (4.7-6.1) kPa (P<0.05). R(aw) increased from 0.156 (0.134-0.263) to 0.169 (0.132-0.271) kPa s/L (P<0.05), sG(aw) decreased, but this was not statistically significantly. In acidosis, BE decreased from -0.2 (-2.0-2.2) to -3.5 (-6.3-1.1) mmol/l and pH decreased from 7.41 (7.39-7.45) to 7.36 (7.31-7.40) (both P<0.01), accompanied by a non-significant decrease in Pa(CO(2)). Changes in R(aw) and sG(aw) were contrary to those in alkalosis, but did not reach statistical significance. Acute metabolic acid-base shifts mildly influence the airway calibre in healthy human subjects.

Для цитирования: Brijker F, van den Elshout F J, Heijdra Y F, Bosch F H, Folgering H T. Effect of acute metabolic acid/base shifts on the human airway calibre.. Respiration physiology. 2001. DOI: 10.1016/s0034-5687(00)00196-1.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.