MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s10792-022-02466-4

Медицинская библиотека · International ophthalmology · 2022

Comparing the accuracy of the new-generation intraocular lens power calculation formulae in axial myopic eyes: a meta-analysis.

Li Hongyu, Ye Zi, Luo Yu, Li Zhaohui

МетаанализСтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To compare the accuracy of the new-generation intraocular lens power calculation formulae in axial myopic eyes.

METHODS

Four databases, PubMed, Web of Science, EMBASE and Cochrane library, were searched to select relevant studies published between Apr 11, 2011, and Apr 11, 2021. Axial myopic eyes were defined as an axial length more than 24.5 mm. There are 13 formulae to participate in the final comparison (SRK/T, Hoffer Q, Holladay I, Holladay II, Haigis for traditional formulae, Barrett Universal II, Olsen, T2, VRF, EVO, Kane, Hill-RBF, LSF for the new-generation formulae). The primary outcomes were the percentage of eyes with a refractive prediction error in ± 0.5D and ± 1.0D.

RESULTS

A total of 2273 eyes in 15 studies were enrolled in the final meta-analysis. Overall, the new-generation formulae showed a relatively more accurate outcome in comparison with traditional formulae. The percentage of eyes with a predictive refraction error in ± 0.5D (± 1.0D) of Kane, EVO and LSF was higher than 80% (95%), which was only significantly different from Hoffer Q (all P < 0.05). Moreover, another two new-generation formulae, Barrett Universal II and Olsen, had higher percentages than SRK/T, Hoffer Q, Holladay I and Haigis for eyes with predictive refraction error in ± 0.5D and ± 1.0D (all P < 0.05). In ± 0.5D group, Hill-RBF was better than SRK/T (P = 0.02), and Holladay I was better than EVO (P = 0.03) and LSF (P = 0.009), and Hoffer Q had a lower percentage than EVO, Kane, Hill-RBF and LSF (P = 0.007, 0.004, 0.002, 0.03, respectively). Barrett Universal II was better than T2 (P = 0.02), and Hill-RBF was better than SRK/T (P = 0.009). No significant difference was found in other pairwise comparison.

CONCLUSION

The new-generation formula is more accurate in intraocular lens power calculation for axial myopic eyes in comparison with the third- or fourth-generation formula.

Для цитирования: Li Hongyu, Ye Zi, Luo Yu, Li Zhaohui. Comparing the accuracy of the new-generation intraocular lens power calculation formulae in axial myopic eyes: a meta-analysis.. International ophthalmology. 2022. DOI: 10.1007/s10792-022-02466-4.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.