Safety and anterior chamber structure of evolution implantable Collamer lens implantation with short white-to-white corneal diameters.

Chen Xun, Chen Fang, Wang Xuanqi, Xu Yilin, Cheng Mingrui, Han Tian, Wang Xiaoying, Zhou Xingtao

СтатьяПеревод пока не подготовлен

Аннотация

INTRODUCTION

To evaluate the safety and anterior chamber structure of implantation of the Evolution (EVO) implantable Collamer lens (EVO-ICL) in patients with short white-to-white (WTW) corneal diameters.

MATERIALS AND

METHODS

The study population was divided into two groups: the experimental group (34 eyes of 34 patients) with WTW corneal diameters of ≤10.6 mm and the control group (59 eyes of 59 patients) with WTW corneal diameters of >10.6 mm. The outcome measures included uncorrected distance visual acuity, corrected distance visual acuity, refractive power, intraocular pressure (IOP), anterior chamber angle, depth, volume, and vault.

RESULTS

The safety indices of the experimental and control groups were 1.17 ± 0.30 and 1.12 ± 0.14, respectively (P > 0.05); the effectiveness indices were 1.16 ± 0.31 and 1.07 ± 0.17, respectively (P > 0.05). The simulation curves of the expected and actual corrections in the experimental and control groups were y = 0.9876x - 0.0927 and y = 0.9799x + 0.0343, respectively. There were no significant differences between the IOPs and anterior chamber structures of the two groups (P > 0.05). The average vaults of the experimental and control groups were 395.76 ± 155.32 and 389.49 ± 135.01 μm, respectively (P > 0.05).

CONCLUSION

EVO-ICL implantation in patients with short WTW corneal diameters (≤ 10.6 mm) was determined to be a safe, effective, and predictable method for correcting myopia. The changes in the anterior chamber structure were still within normal limits after the surgery, the IOP remained stable, and the ideal vault was achieved after the surgery.

Для цитирования: Chen Xun, Chen Fang, Wang Xuanqi, Xu Yilin, Cheng Mingrui, Han Tian, Wang Xiaoying, Zhou Xingtao. Safety and anterior chamber structure of evolution implantable Collamer lens implantation with short white-to-white corneal diameters.. Frontiers in medicine. 2022. DOI: 10.3389/fmed.2022.928245.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.