MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jcrs.2011.11.031

Медицинская библиотека · Journal of cataract and refractive surgery · 2012

Effects of steep meridian incision on corneal astigmatism in phacoemulsification cataract surgery.

Rho Chang Rae, Joo Choun-Ki

Сравнительное исследованиеСтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

PURPOSE: To evaluate surgically induced astigmatism (SIA) when the clear corneal incision is located on the preoperative steep meridian of the corneal astigmatism in phacoemulsification cataract surgery.

SETTING

Seoul St. Mary's Hospital, Seoul, South Korea.

DESIGN

Comparative case series.

METHODS

Patients with preoperative corneal astigmatism greater than 0.50 diopter (D) were evaluated. The corneal incision meridian was chosen by rounding the steep corneal meridian to the closest 10 degrees. All incisions were enlarged to 3.0 mm before intraocular lens implantation. Patients were grouped according to incision location (temporal, superotemporal, superior). Preoperative keratometric data were compared with data collected 2 months postoperatively. Polar value analysis was used to analyze the SIA. The Hotelling trace test was used for comparison of intraindividual changes.

RESULTS

The study evaluated 95 patients (30 eyes temporal incision, 32 eyes superotemporal incision, 33 eyes superior incision). Two months postoperatively, the combined mean polar values for SIA changed significantly in the temporal group (Hotelling T(2) = 0.418; P=.008), superotemporal group (Hotelling T(2) = 1.078; P<.001), and superior incision group (Hotelling T(2) = 1.175; P<.001). The SIA was 0.28 @ 79, 0.40 @ 85, and 0.46 @ 92, respectively.

CONCLUSIONS

Choosing the corneal incision based on the preoperative steep meridian significantly decreased keratometric astigmatism at the temporal, superotemporal, and superior locations. Thus, it is desirable to place the corneal incision on the steep meridian in eyes with corneal astigmatism higher than 0.50 D.

Для цитирования: Rho Chang Rae, Joo Choun-Ki. Effects of steep meridian incision on corneal astigmatism in phacoemulsification cataract surgery.. Journal of cataract and refractive surgery. 2012. DOI: 10.1016/j.jcrs.2011.11.031.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.