MedElevator Войти в исследования
← Поиск публикаций

DOI 10.5301/ejo.5000100

Медицинская библиотека · European journal of ophthalmology · 2012

Controlled clinical trial comparing biaxial microincision with coaxial small incision for cataract surgery.

Dick H Burkhard

СтатьяРандомизированное исследованиеПеревод пока не подготовлен

Аннотация

PURPOSE: Clinical outcomes of biaxial microincision versus coaxial small incision cataract surgery were compared in a prospective, controlled, paired-eye clinical study.

METHODS

A total of 84 eyes of 42 patients underwent cataract surgery using the biaxial microincision (B-MICS) technique in either the right or left eye. The fellow eye was to undergo cataract surgery using the standard coaxial small incision (SICS) technique. All surgeries were performed using the Stellaris Vision Enhancement System and all eyes were implanted with an aspheric microincision intraocular lens (IOL). The 1.2-mm B-MICS incision was widened to 1.8 mm for IOL insertion. The main outcome measure was the change from baseline best-corrected visual acuity (BCVA). Secondary outcome measures were uncorrected visual acuity (UCVA), surgically induced astigmatism (SIA), manifest subjective refraction in spherical equivalent (MRSE), absolute phacoemulsification time (APT), effective phacoemulsification time (EPT), mean phacoemulsification power, and endothelial cell count (ECC). Follow-up was at 1 day, 3 days, 1 week, and 2 months.

RESULTS

The treatment groups did not differ in baseline characteristics. Improvement in BCVA over baseline logarithm of the minimum angle of resolution (logMAR) was statistically significantly greater with B-MICS than SICS at 1 day (B-MICS -0.1, SICS -0.05; 95% CI -0.26 to -0.05, p=0.005). Mean improvement in UCVA from baseline was greater with B-MICS at 1 day (B-MICS -0.33, SICS -0.12; 95% CI -0.35 to -0.10, p=0.001), 3 days (B-MICS -0.39, SICS -0.26; 95% CI -0.22 to -0.02, p=0.022), 1 week (B-MICS -0.44, SICS -0.33; 95% CI -0.20 to -0.009, p=0.033), and 2 months (B-MICS -0.47, SICS 0.38; 95% CI -0.19 to +0.002, p =0.054). At 2 months, SIA was significantly lower with B-MICS than SICS (B-MICS 0.70 D, SICS 0.89 D; 95% CI -0.39 to -0.1, p=0.045), as was endothelial cell loss (B-MICS -1.4%, SICS -7.8%; p=0.05). The EPT was lower with B-MICS (B-MICS 1.60 s, SICS 2.80 s; 95% CI -1.68 to -0.77, p<0.001) with no difference in mean phaco power.

CONCLUSIONS

Compared to the standard small incision technique, B-MICS showed earlier improvement in BCVA, better overall UCVA, less SIA, and less endothelial cell loss.

Для цитирования: Dick H Burkhard. Controlled clinical trial comparing biaxial microincision with coaxial small incision for cataract surgery.. European journal of ophthalmology. 2012. DOI: 10.5301/ejo.5000100.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.