MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jcrs.2011.07.035

Медицинская библиотека · Journal of cataract and refractive surgery · 2012

Central vault after phakic intraocular lens implantation: correlation with anterior chamber depth, white-to-white distance, spherical equivalent, and patient age.

Alfonso José F, Fernández-Vega Luis, Lisa Carlos, Fernandes Paulo, Jorge Jorge, Montés Micó Robert

Сравнительное исследованиеСтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

PURPOSE: To compare the central postoperative vault of a phakic intraocular lens (pIOL) to correct myopia, myopic astigmatism, and hyperopia and identify ocular and lens parameters that might predict the vault amount.

SETTING

Fernández-Vega Ophthalmological Institute, Oviedo, Spain.

DESIGN

Cohort study.

METHODS

Three months after implantation of Implantable Collamer Lens pIOLs to correct myopia, hyperopia, and myopic astigmatism, central vault was measured using optical coherence tomography. Patients were divided into groups according to the preoperative anterior chamber depth (ACD) to compare the effects of ACD, white-to-white (WTW) distance, and lens diameter on postoperative pIOL vault.

RESULTS

Hyperopic pIOLs had statistically significantly lower vault followed by myopic pIOLs and toric pIOLs, which had a higher mean value and narrower range (260 to 860 μm). Measured vaults had a positive correlation with preoperative ACD (r = .32, P<.001) and WTW (r = .29, P<.001) and a negative correlation with preoperative spherical equivalent (SE) (r = -0.21, P<.001) and patient age (r = -0.12, P=.025). Eyes with a vault of 250 μm or less had a shallower ACD than eyes with a vault between 250 μm and 750 μm (mean difference -0.11 mm; P=.012) and those with a vault greater than 750 μm (mean difference -0.25 mm; P<.001).

CONCLUSIONS

Central vaulting was lower in hyperopic eyes. Current nomograms for pIOL diameter selection based on ACD and WTW might yield ideal vault and may have to be adjusted for older patients, shallower ACD, lower WTW, and lower SE.

Для цитирования: Alfonso José F, Fernández-Vega Luis, Lisa Carlos, Fernandes Paulo, Jorge Jorge, Montés Micó Robert. Central vault after phakic intraocular lens implantation: correlation with anterior chamber depth, white-to-white distance, spherical equivalent, and patient age.. Journal of cataract and refractive surgery. 2012. DOI: 10.1016/j.jcrs.2011.07.035.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.