MedElevator Войти в исследования
← Поиск публикаций

DOI 10.5301/ejo.5000090

Медицинская библиотека · European journal of ophthalmology · 2012

In vivo assessment of higher-order aberrations after AcrySof toric intraocular lens implantation: a comparative study.

Scialdone Antonio, Raimondi Giulia, Monaco Gaspare

Сравнительное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To compare higher-order aberrations (HOAs) and optical quality in eyes implanted with AcrySof SN60TT toric intraocular lens (IOL) or with non-toric AcrySof SN60AT IOL (Alcon Laboratories, Inc., Fort Worth, TX).

METHODS

This was a prospective, consecutive, nonrandomized, interventional, comparative study. One hundred eyes with cataract in 56 patients were included (SN60TT group, n=50; SN60AT group, n=50). Patients underwent phacoemulsification through a 2.2-mm temporal corneal incision. Postoperative HOAs, point spread function (PSF) and modulation transfer function (MTF), residual objective refractive astigmatism, and IOL alignment were evaluated using Optical Path Difference (OPD)-Scan II (Nidek, Gamagori, Japan). A novel technique to calculate IOL axis alignment was introduced.

RESULTS

One year postoperatively, no statistical difference in corneal, intraocular, and total HOAs, Strehl ratio, and MTF based on HOAs was found between groups. Toric IOL patients had a net residual refractive astigmatism (M) of 0.44 D±0.47; the difference between expected and obtained astigmatism (M) was 0.043 D (p=0.16). Toric IOL axis misalignment was 2.65±2.39 degrees and no correlation with HOAs was found.

CONCLUSIONS

AcrySof SN60TT determines HOAs comparable to the non-toric version providing a good optical quality, and predictably corrects corneal cylinder with a stable postoperative alignment. The OPD-Scan II might be regarded as a fast and reliable method of toric IOL analysis.

Для цитирования: Scialdone Antonio, Raimondi Giulia, Monaco Gaspare. In vivo assessment of higher-order aberrations after AcrySof toric intraocular lens implantation: a comparative study.. European journal of ophthalmology. 2012. DOI: 10.5301/ejo.5000090.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.