MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3928/1081597x-20111018-02

Медицинская библиотека · Journal of refractive surgery (Thorofare, N.J. : 1995) · 2011

Comparison of higher order aberrations after implantable Collamer Lens implantation and wavefront-guided LASEK in high myopia.

Shin Joo Youn, Ahn Hyunseok, Seo Kyoung Yul, Kim Eung Kweon, Kim Tae-Im

Сравнительное исследованиеСтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

PURPOSE: To compare changes in ocular higher order aberrations (HOAs) after Visian Implantable Collamer Lens (ICL, STAAR Surgical Co) implantation and wavefront-guided laser epithelial keratomileusis (WFG-LASEK) to correct high myopia.

METHODS

This prospective case series comprised 30 eyes (18 patients) that underwent ICL implantation (ICL group) and 33 eyes (18 patients) that underwent WFG-LASEK (WFG-LASEK group). All eyes had spherical equivalent of -6.00 to -9.00 diopters. Entire ocular, internal optic, and corneal HOAs were measured before surgery and 3 months after surgery using a laser ray tracing aberrometer. Contrast sensitivity testing was performed in 10 eyes from each group at a photopic light level of 85 cd/m(2) and a mesopic level of 3 cd/m(2) 3 months after surgery.

RESULTS

In the ICL group, HOAs changed for the entire ocular trefoil-y, spherical aberration, internal optic spherical aberration, and corneal trefoil-y. In the WFG-LASEK group, increased HOAs were observed for total HOAs, entire ocular and corneal spherical aberration, secondary astigmatism, and tetrafoil. The ICL group had lower induced aberration values of entire ocular and corneal HOAs compared with the WFG-LASEK group. No significant differences in contrast sensitivity values between groups at the photopic level were noted; however, contrast sensitivity values were significantly lower for 3 (P=.01) and 6 cycles per degree (P<.001) in the WFG-LASEK group at the mesopic level. At the mesopic level, total HOAs, trefoil-y, spherical aberration, and secondary astigmatism were higher in the WFG-LASEK group.

CONCLUSIONS

Implantable Collamer Lens implantation induced fewer ocular and corneal HOAs and resulted in better contrast sensitivity at mesopic levels than WFG-LASEK in eyes with high myopia.

Для цитирования: Shin Joo Youn, Ahn Hyunseok, Seo Kyoung Yul, Kim Eung Kweon, Kim Tae-Im. Comparison of higher order aberrations after implantable Collamer Lens implantation and wavefront-guided LASEK in high myopia.. Journal of refractive surgery (Thorofare, N.J. : 1995). 2011. DOI: 10.3928/1081597x-20111018-02.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.