MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3109/02713683.2011.622851

Медицинская библиотека · Current eye research · 2011

Comparison of corneal aberrations after biaxial microincision and microcoaxial cataract surgeries: a prospective study.

Can İzzet, Bayhan Hasan Ali, Çelik Hale, Ceran Başak Bostancı

Сравнительное исследованиеСтатьяРандомизированное исследованиеПеревод пока не подготовлен

Аннотация

PURPOSE: To compare the effects of biaxial microincision cataract surgery (B-MICS) and microcoaxial cataract surgery (C-MICS) techniques on corneal optical quality.

MATERIALS AND

METHODS

In this prospective study, 40 eyes underwent B-MICS and 40 eyes C-MICS. Corneal aberrations were derived from conversion of the corneal elevation profile into corneal wavefront data with 6.0  mm aperture diameter using Zernike polynomials by corneal topography preoperatively and 1 month postoperatively. Both magnitude and axes of surgically induced corneal aberrations were calculated.

RESULTS

Mean final incision widths were 1.80 ± 0.09  mm and 1.89 ± 0.11  mm (p = 0.062) in B-MICS and C-MICS groups, respectively. There were no significant changes in total and higher order root mean square in both groups postoperatively. In B-MICS group, all aberration terms were similar, before and after surgery. However, vertical coma (p = 0.002), vertical trefoil (p < 0.001) and primary trefoil (p = 0.042) significantly increased postoperatively in the C-MICS group. Except surgically induced trefoil (p = 0.047), there was no significant difference in all surgically induced corneal aberrations between groups. The axes of the induced trefoil were found to be mostly related and close to the incision site in both groups which was more prominent in the C-MICS group.

CONCLUSIONS

Microincision cataract surgery techniques performed through sub-1.9  mm clear corneal incisions do not generally degrade optical quality of the cornea while only small amount of higher order aberrations seem to be induced with C-MICS technique.

Для цитирования: Can İzzet, Bayhan Hasan Ali, Çelik Hale, Ceran Başak Bostancı. Comparison of corneal aberrations after biaxial microincision and microcoaxial cataract surgeries: a prospective study.. Current eye research. 2011. DOI: 10.3109/02713683.2011.622851.

Предметные рубрики MeSH

Подготовка и перевод публикации