DOI 10.1097/ico.0b013e31821821e1
Intrastromal corneal ring segment implantation by femtosecond laser for the correction of residual astigmatism after penetrating keratoplasty.
Аннотация
PURPOSE: To evaluate the safety and efficacy of intracorneal ring segments (ICRSs) aided by femtosecond (FS) laser for the correction of residual astigmatism after penetrating keratoplasty (PKP).
METHODS
This retrospective noncomparative study comprised 14 eyes of 14 patients with high astigmatism after PKP who had ICRS implantation by femtosecond laser. The study evaluated uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), refractive astigmatism, and corneal maximum curvature.
RESULTS
The CDVA postoperatively improved after 3 months (P < 0.001) and 6 months (P < 0.001) compared with CDVA preoperatively. The CDVA at 3 months was similar to that at 6 months (P > 0.999) as well as the UDVA (P = 0.276). The preoperative astigmatism was higher than that after surgery (P = 0.001). The preoperative maximum curvature was higher than that of the postoperative maximum curvature (P < 0.001).
CONCLUSIONS
The implantation of ICRSs using the femtosecond laser for residual astigmatism post-PKP was safe and showed satisfactory results. It reduced refractive astigmatism and maximum corneal curvature and improved UDVA and CDVA.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.