MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jcrs.2011.02.028

Медицинская библиотека · Journal of cataract and refractive surgery · 2011

Results of higher power toric intraocular lens implantation.

Hoffmann Peter C, Auel Sebastian, Hütz Werner W

СтатьяМногоцентровое исследованиеПеревод пока не подготовлен

Аннотация

PURPOSE: To evaluate the efficacy, predictability, and safety of coaxial microincision phacoemulsification and toric intraocular lens (IOL) implantation in eyes with high corneal astigmatism.

SETTING

Two eye clinics in Germany.

DESIGN

Case series.

METHODS

Routine cataract extraction using 2.2 mm coaxial phaco equipment and Acrysof toric IOL (3.00 to 6.00 diopters [D] cylinder) implantation were performed. Examinations included optical biometry, Haigis IOL calculation, topography, and objective and subjective refractions. Retroillumination images were used to evaluate IOL alignment. Postoperative examinations were scheduled at 1 week and 3 months.

RESULTS

The study enrolled 40 eyes (30 patients). The mean preoperative keratometric cylinder was 3.55 ± 0.73 D (range 2.64 to 5.39 D) and the mean 3-month postoperative subjective cylinder, 0.67 ± 0.32 D. The mean logMAR uncorrected distance visual acuity improved from 0.93 to 0.20 and the mean logMAR CDVA, from 0.41 to 0.09. The mean prediction error (spherical equivalent) was +0.14 ± 0.44 D. The mean IOL rotation between 1 week and 3 months was 0.23 ± 1.9 degrees clockwise. The mean surgically induced astigmatism was 0.08 ± 0.41 D. The alignment error was below 10 degrees in 97.5% of cases. The mean vector change in refractive cylinder between 1 week and 3 months was 0.31 ± 0.19 D. The Alpins correction index was +1.01, indicating a slight tendency toward overcorrection.

CONCLUSIONS

Coaxial microincision phacoemulsification with toric IOL safely and predictably reduced high corneal astigmatism and improved surgical outcomes. Thorough planning and precise execution are necessary.

Для цитирования: Hoffmann Peter C, Auel Sebastian, Hütz Werner W. Results of higher power toric intraocular lens implantation.. Journal of cataract and refractive surgery. 2011. DOI: 10.1016/j.jcrs.2011.02.028.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.