MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3390/ijerph22010047

Медицинская библиотека · International journal of environmental research and public health · 2024

Evaluation of an Artificial Intelligence-Based Tool and a Universal Low-Cost Robotized Microscope for the Automated Diagnosis of Malaria.

Rubio Maturana Carles, de Oliveira Allisson Dantas, Zarzuela Francesc, Mediavilla Alejandro, Martínez-Vallejo Patricia, Silgado Aroa, Goterris Lidia, Muixí Marc, Abelló Alberto, Veiga Anna, López-Codina Daniel, Sulleiro Elena, Sayrol Elisa, Joseph-Munné Joan

СтатьяОценочное исследованиеПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

The gold standard diagnosis for malaria is the microscopic visualization of blood smears to identify Plasmodium parasites, although it is an expert-dependent technique and could trigger diagnostic errors. Artificial intelligence (AI) tools based on digital image analysis were postulated as a suitable supportive alternative for automated malaria diagnosis. A diagnostic evaluation of the iMAGING AI-based system was conducted in the reference laboratory of the International Health Unit Drassanes-Vall d'Hebron in Barcelona, Spain. iMAGING is an automated device for the diagnosis of malaria by using artificial intelligence image analysis tools and a robotized microscope. A total of 54 Giemsa-stained thick blood smear samples from travelers and migrants coming from endemic areas were employed and analyzed to determine the presence/absence of Plasmodium parasites. AI diagnostic results were compared with expert light microscopy gold standard method results. The AI system shows 81.25% sensitivity and 92.11% specificity when compared with the conventional light microscopy gold standard method. Overall, 48/54 (88.89%) samples were correctly identified [13/16 (81.25%) as positives and 35/38 (92.11%) as negatives]. The mean time of the AI system to determine a positive malaria diagnosis was 3 min and 48 s, with an average of 7.38 FoV analyzed per sample. Statistical analyses showed the Kappa Index = 0.721, demonstrating a satisfactory correlation between the gold standard diagnostic method and iMAGING results. The AI system demonstrated reliable results for malaria diagnosis in a reference laboratory in Barcelona. Validation in malaria-endemic regions will be the next step to evaluate its potential in resource-poor settings.

Для цитирования: Rubio Maturana Carles, de Oliveira Allisson Dantas, Zarzuela Francesc, Mediavilla Alejandro, Martínez-Vallejo Patricia, Silgado Aroa, Goterris Lidia, Muixí Marc, Abelló Alberto, Veiga Anna, López-Codina Daniel, Sulleiro Elena, Sayrol Elisa, Joseph-Munné Joan. Evaluation of an Artificial Intelligence-Based Tool and a Universal Low-Cost Robotized Microscope for the Automated Diagnosis of Malaria.. International journal of environmental research and public health. 2024. DOI: 10.3390/ijerph22010047.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.