Transperineal Ultrasound Evaluation of Intravaginal Electrical Stimulation Parameters.

Vereeck Sascha, Rolnik Daniel L, Webb Janetta, Warty Ritesh Rikain, Rosamilia Anna

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVES

To identify the optimal vaginal stimulation region by examining the effect of intravaginal electrical stimulation (IVES) on pelvic floor muscles (PFM) as seen on transperineal ultrasound (TPUS).

METHODS

Open-label cross-sectional study of women presenting with pelvic organ prolapse. Women ≥18 years and English speaking were included. Exclusion criteria were any contraindications for IVES. NeuroTrac® Continence was used for IVES. Simultaneously, TPUS was performed to assess levator hiatus (LH) length. Initially, the IVES probe was placed with the tip at the posterior fornix, then retracted in 2 cm increments. The primary outcome was the identification of the optimal target region for IVES as defined by the largest reduction in LH length. Secondary outcomes included patient acceptability, and the feasibility of performing IVES and TPUS simultaneously. Statistical analysis was performed with SPSS28.

RESULTS

On maximum voluntary PFM contraction, a 5.75% reduction in LH length was seen (p = .002). Comparatively, when IVES was applied with the tip of the probe at or 2 cm distal to the posterior fornix, 10.83% and 10.17% reductions in LH length were seen, respectively (both p = .002). At 4 and 6 cm distal locations, 6.00% (p = .002) and 3.17% (p = .016) reductions were observed, respectively.

CONCLUSION

Intravaginal electrical stimulation should be performed near the posterior fornix. IVES and TPUS can be performed concomitantly.

Для цитирования: Vereeck Sascha, Rolnik Daniel L, Webb Janetta, Warty Ritesh Rikain, Rosamilia Anna. Transperineal Ultrasound Evaluation of Intravaginal Electrical Stimulation Parameters.. Journal of ultrasound in medicine : official journal of the American Institute of Ultrasound in Medicine. 2025. DOI: 10.1002/jum.70104.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.