MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jstrokecerebrovasdis.2016.01.041

Медицинская библиотека · Journal of stroke and cerebrovascular diseases : the official journal of National Stroke Association · 2016

Moyamoya Vessel Pathology Imaged by Ultra-High-Field Magnetic Resonance Imaging at 7.0 T.

Dengler Nora F, Madai Vince I, Wuerfel Jens, von Samson-Himmelstjerna Federico C, Dusek Petr, Niendorf Thoralf, Sobesky Jan, Vajkoczy Peter

Сравнительное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Prompt diagnosis of vessel pathology and appropriate treatment of moyamoya vasculopathy (MMV) are essential to improve long-term prognosis. The aims of our study were to explore the diagnostic value of ultra-high-field (UHF) magnetic resonance imaging at 7.0 T in MMV patients and to compare the applicability of two different 7.0 T vessel imaging modalities to 3.0 T magnetic resonance angiography (MRA) and digital subtraction angiography (DSA).

METHODS

In a World Health Organization-registered and prospective imaging trial, patients were investigated at 7.0 T magnetization-prepared rapid-acquisition gradient echo (MPRAGE)-MRA and time-of-flight (TOF)-MRA, 3.0 T TOF-MRA, and by DSA.

RESULTS

Six patients were included in our study and evaluated for MMV. 3.0 T TOF-MRA and 7.0 T MPRAGE-MRA were able to depict the complete major vascular tree and confirmed MMV-specific steno-occlusions of major intracranial arteries, as previously identified by DSA. 7.0 T TOF-MRA was limited to visualization of the circle of Willis as well as the internal carotid artery only. Donor vessels for bypass surgery (i.e., branches of superficial temporal artery) could be sufficiently visualized with all magnetic resonance modalities.

CONCLUSIONS

Our results indicate that a specific 7.0 T vascular imaging protocol yields diagnostic information about vessel pathology in MMV that approximates conventional DSA. 7.0 T MPRAGE was superior to 7.0 T TOF-MRA due to shorter scanning times and better brain coverage. To date, however, limited availability of 7.0 T technology in medical facilities as well as technical and procedural constraints excludes a fair amount of patients from the clinical 7.0 T imaging process.

Для цитирования: Dengler Nora F, Madai Vince I, Wuerfel Jens, von Samson-Himmelstjerna Federico C, Dusek Petr, Niendorf Thoralf, Sobesky Jan, Vajkoczy Peter. Moyamoya Vessel Pathology Imaged by Ultra-High-Field Magnetic Resonance Imaging at 7.0 T.. Journal of stroke and cerebrovascular diseases : the official journal of National Stroke Association. 2016. DOI: 10.1016/j.jstrokecerebrovasdis.2016.01.041.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.