MedElevator Войти в исследования
← Поиск публикаций

DOI 10.2147/opth.s417336

Медицинская библиотека · Clinical ophthalmology (Auckland, N.Z.) · 2023

Accuracy of Traditional and Modern Formulas for Intraocular Lens Power Calculation After Radial Keratotomy Using Standard Keratometry.

Helaly Hany Ahmed, Elhady Amr Mohamed, Elnaggar Osama Ramadan

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To compare the accuracy of multiple traditional and modern intraocular lens (IOL) power calculation formulas in post-radial keratotomy (RK) patients undergoing cataract surgery.

METHODS

This retrospective case series included 50 eyes with prior RK who underwent routine phacoemulsification surgery with single-piece acrylic IOL implantation (A constant = 118.8). Outcomes of multiple formulas were calculated. Included formulas were SRK/T, Holladay 1, Holladay 2, Haigis, Barrett True-K, Haigis and Barrett True-K (target refraction of 0.50 D), Barrett Universal II, Kane, PEARL-DGS, Shammas no history, DK SRK/T, DK SRK/T (target refraction of 0.50 D), Double K (DK) Holladay 1, and DK Holladay 1 (target refraction of 0.50 D). Averages of multiple combinations of best-performing single formulas were calculated. Primary outcome is mean absolute error (MAE).

RESULTS

Haigis (with -0.50 D target refraction) and DK SRK/T showed the lowest mean and median absolute errors (MedAE) followed by Haigis, Barrett True-K, and Barrett True-K (with -0.50 D target refraction). Combinations of 3, 4, or 5 of best performing single formulas yielded good results with >60% of cases within +0.50 D of intended refraction and MAE around 0.50 D. The best performing formulas with flatter K readings were PEARL-DGS and Haigis (with additional -0.50 D target refraction) with MAE of 0.72 + 0.71 D and 0.70 + 0.70 D, respectively, followed by Barrett True-K (with intended -0.50 D target refraction) with MAE of 0.75 + 0.63 D.

CONCLUSION

Using an average of three or more Haigis (with -0.50 D target refraction), the Barrett True-K, DK Holladay 1, and DK SRK/T formulas showed better outcomes than using a single formula for IOLMaster 700 standard K readings. The PEARL-DGS formula showed better accuracy in eyes with flatter K readings (<38 D).

Для цитирования: Helaly Hany Ahmed, Elhady Amr Mohamed, Elnaggar Osama Ramadan. Accuracy of Traditional and Modern Formulas for Intraocular Lens Power Calculation After Radial Keratotomy Using Standard Keratometry.. Clinical ophthalmology (Auckland, N.Z.). 2023. DOI: 10.2147/opth.s417336.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.