Novel apical coring device for apicoaortic conduit insertion to treat off-pump aortic stenosis, coronary disease, and lung cancer.

Di Giammarco Gabriele, Canosa Carlo, Foschi Massimiliano, Mucilli Felice, Marinelli Daniele, Nuzzo Nicoletta, Testa Nicola

Клинический случайСтатьяПеревод пока не подготовлен

Аннотация

The surgical treatment of concomitant cardiac disease and lung cancer represents a challenge. We report the case of a 66-year-old high-risk female patient with severe aortic stenosis as well as severely impaired left ventricular function associated with coronary artery disease involving the left anterior descending artery complicated from a severe functional mitral regurgitation in which an early-stage non-small cell carcinoma was incidentally discovered during workup. Because of the possibility of potential negative impact of cardiopulmonary bypass on the cancer prognosis and the severe impairment of systolic function of the left ventricle that impeded the treatment of lung cancer as the first step of such a complex treatment, we planned to treat all the diseases in a single-stage procedure. Using an automated delivering system composed of a ventricular connector (Correx AVB; Correx, Inc, Waltham, MA USA), we were able to perform an apicoaortic bypass as well as a left anterior descending revascularization using the left internal thoracic artery, both on a beating heart without the aid of cardiopulmonary bypass and a three-segmentectomy of the left upper lobe with the removal of paraaortic nodes. Six months postoperatively, she was asymptomatic with a noticeable increase of systolic function, a mild mitral incompetence, and no appearance of tumor recurrence. To the best of our knowledge, this is the first case described in the literature in which three major problems involving cardiac valves, coronary arteries, and the lung have been treated in one stage without cardiopulmonary bypass.

Для цитирования: Di Giammarco Gabriele, Canosa Carlo, Foschi Massimiliano, Mucilli Felice, Marinelli Daniele, Nuzzo Nicoletta, Testa Nicola. Novel apical coring device for apicoaortic conduit insertion to treat off-pump aortic stenosis, coronary disease, and lung cancer.. Innovations (Philadelphia, Pa.). 2015. DOI: 10.1097/imi.0000000000000128.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.