MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1148/radiol.251663

Медицинская библиотека · Radiology · 2026

Photon-counting CT versus Energy-integrating Detector CT Performance for Various BMI and Tumor Sizes in Lung Cancer.

Zhou Yuhan, Guo Xiaoxu, Lei Limin, Zhang Haojie, Wang Zhihao, Guo Yifan, Wang Yajie, Tao Lina, Sun Hao, Yue Songwei

СтатьяСравнительное исследованиеПеревод пока не подготовлен

Аннотация

Background Data on the detection of enhancement-related malignant features and applicable scenarios for low-dose ultrahigh-resolution photon-counting CT (PCCT) in lung cancer are lacking. Purpose To compare the benefits of PCCT versus energy-integrating detector (EID) CT at contrast-enhanced chest CT for different populations with lung cancer. Materials and Methods This prospective study enrolled 459 consecutive participants with lesions who underwent either low-dose contrast media PCCT (1 mL/kg at 2 mL/sec) or standard-dose EID CT (1.2 mL/kg at 3 mL/sec) from June to December 2024. The EID CT group was selected using propensity score matching. Images were reconstructed into five section thicknesses (PCCT: 5 mm, 1 mm, 0.4 mm; EID CT: 5 mm, 1 mm). Adverse reactions and contrast-induced acute kidney injury were recorded. Lesion image quality, malignant radiologic features, diagnostic confidence, and subgroup (body mass index [calculated as weight in kilograms divided by height in meters squared], tumor size) were analyzed using a five-point Likert scale. Statistical data were compared using one-way analysis of variance and post hoc comparisons. Results Among 200 participants after propensity score matching (mean age, 61.66 years ± 9.60 [SD]), PCCT reduced radiation and iodine exposure by 66.34% (effective dose, 1.36 mSv vs 4.04 mSv) and 26.57% (iodine load, 20.62 mg vs 28.08 mg; P < .001), respectively, lowering adverse reactions and contrast-induced acute kidney injury (2% [two of 100 participants] vs 9% [nine of 100], P = .03; 1% [one of 100] vs 7% [seven of 100], P = .03). PCCT at 0.4 mm showed higher detection and diagnostic confidence for enhancement-related malignant features (PCCT vs EID CT, 291-340 findings vs 194-255 findings [Likert 5 {IQR, 4-5} vs Likert 3 {IQR, 3-4}]; P < .001) and yielded higher overall image quality (Likert 5 [IQR, 5-5]; P < .05) in normal weight participants and structures within enhanced lesions of less than or equal to 3 cm (Likert 4 [IQR, 3-4] vs Likert 3 [IQR, 3-3]; P < .001). Conclusion PCCT reduced radiation exposure, adverse reactions, and contrast-induced acute kidney injury compared with EID CT. With a 0.4-mm section thickness, PCCT improved overall image quality, detection of enhancement-related malignant features, and diagnostic confidence, making it suitable for various body mass index and small lesions (T1 stage). © The Author(s) 2026. Published by the Radiological Society of North America under a CC BY 4.0 license. Supplemental material is available for this article.

Для цитирования: Zhou Yuhan, Guo Xiaoxu, Lei Limin, Zhang Haojie, Wang Zhihao, Guo Yifan, Wang Yajie, Tao Lina, Sun Hao, Yue Songwei. Photon-counting CT versus Energy-integrating Detector CT Performance for Various BMI and Tumor Sizes in Lung Cancer.. Radiology. 2026. DOI: 10.1148/radiol.251663.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.