Molecular Epidemiology of Clinical Infections Caused by Serratia marcescens Complex in a Tertiary Care Hospital System: Insights From Whole-Genome Sequencing.
Аннотация
BACKGROUND
Serratia marcescens is an opportunistic AmpC β-lactamase-producing Enterobacterales associated with intensive care unit outbreaks, causing high morbidity and mortality. The spatiotemporal dynamics of Serratia species and their implications for hospital infection prevention and control remain understudied.
METHODS
We prospectively identified patient culture specimens in a multihospital academic healthcare system from 2022 to 2024. We included first-time isolates of S. marcescens identified via culture and confirmed by matrix-assisted laser desorption ionization time-of-flight mass spectrometry (MALDI-TOF MS). Isolates underwent whole-genome sequencing on the Illumina NextSeq 2000 platform. We queried assembled genomes using the Comprehensive Antibiotic Resistance Database to identify resistance genes and predict resistomes. We constructed a maximum-likelihood phylogenetic tree using GTDB-Tk-assigned taxonomies. We identified possible links between patients if there was a spatiotemporal overlap and the average nucleotide identity (ANI) of a sequence pair was > 99.0%. We collected relevant patient characteristics via retrospective chart review and analyzed data using descriptive statistics.
RESULTS
Of 147 identified isolates, we included 125. Phenotypic testing suggested either inducible or derepressed AmpC expression in all isolates. Whole-genome sequencing found species-level discordance with MALDI-TOF MS in 64 (51.2%) isolates, suggesting the presence of multiple members of the recently described S. marcescens complex causing hospital- or community-associated infections. Only 1 isolate pair had a spatiotemporal link and ANI > 99.0%.
CONCLUSIONS
Between-patient transmission of S. marcescens complex outside of outbreaks is likely rare. Current MALDI-TOF MS-based identification methods are insufficient to identify S. marcescens complex and laboratory reporting should be modified to report only to the level of the complex.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.