DOI 10.1016/j.joms.2017.11.010

Медицинская библиотека · Journal of oral and maxillofacial surgery : official journal of the American Association of Oral and Maxillofacial Surgeons · 2017

A 3-Dimensional Approach for Analysis in Orthognathic Surgery-Using Free Software for Voxel-Based Alignment and Semiautomatic Measurement.

Stokbro Kasper, Thygesen Torben

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: In orthognathic surgery, the repeatability of 3-dimensional (3D) measurements is limited by the need for manual reidentification of reference points, which can incorporate errors greater than 1 mm for every 4 repeated measurements. This report describes a semiautomatic approach to decrease the manual reidentification error. This study evaluated the repeatability of surgical outcome measurements using the semiautomatic approach. Furthermore, a step-by-step guide is provided to enable researchers and clinicians to perform the 3D analysis by themselves.

MATERIALS AND

METHODS

Evaluating surgical outcome consists of 2 parts. First, the scans are aligned at the anterior cranial base. Second, a semiautomatic approach is used to place 3 dental reference points at exactly the same sites of the pre- and postoperative maxilla. Because the maxilla is repositioned during surgery but otherwise unaltered, the reference points should be identical if the pre- and postoperative scans are aligned at the maxilla. Therefore, the authors propose the insertion of reference points on the preoperative scan and then repositioning a copy of the preoperative reference points relative to the postoperative scan. To align the reference points on the postoperative scan, the hard palate is used as a mutual maxillary reference structure. A reproducibility test was performed in 10 participants by analyzing the difference between repeated measurements.

RESULTS

Repeated linear measurements differed by less than 0.1 mm along all 3 axes (standard deviations, <0.1 mm). The 2 largest differences between repeated measurements were 0.33 mm along the superoinferior axis and 0.29 along the anteroposterior axis. Repeated rotational measurements differed by less than 0.1° around all 3 axes (standard deviations, ≤0.1°).

CONCLUSION

The semiautomatic approach showed excellent linear and angular repeatability. The algorithm can be implemented in the clinical evaluation of orthognathic surgical outcome and postoperative relapse.

Для цитирования: Stokbro Kasper, Thygesen Torben. A 3-Dimensional Approach for Analysis in Orthognathic Surgery-Using Free Software for Voxel-Based Alignment and Semiautomatic Measurement.. Journal of oral and maxillofacial surgery : official journal of the American Association of Oral and Maxillofacial Surgeons. 2017. DOI: 10.1016/j.joms.2017.11.010.