MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3928/23258160-20160324-03

Медицинская библиотека · Ophthalmic surgery, lasers & imaging retina · 2016

OCT Angiography Findings in Acute Central Serous Chorioretinopathy.

Feucht Nikolaus, Maier Matthias, Lohmann Chris P, Reznicek Lukas

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND AND

OBJECTIVE

To describe optical coherence tomography angiography (OCTA) findings in patients with acute central serous chorioretinopathy (CSC) compared to conventional imaging methods.

PATIENTS AND

METHODS

A consecutive series of 11 eyes from 10 healthy patients with acute CSC were included and underwent fluorescein angiography (FA), indocyanine green angiography (ICGA), OCT, fundus autofluorescence (FAF), and OCTA. Obtained OCTA images were evaluated for the presence of serous detachments of the neurosensory retina, leakage points, or other altered findings and compared to conventional imaging devices.

RESULTS

In four out of 11 eyes, it was possible to detect detached retina adjacent to the leakage point in OCTA images, compared with four of 11 eyes using FA, five of 11 eyes using ICGA, 11 of 11 eyes using SD-OCT, and four of 11 eyes using FAF. In five out of 11 eyes, irregular flow patterns were observed on OCTA images through the choriocapillaris. OCTA images could not identify leakage points in any of the included eyes, compared with 11 out of 11 eyes on FA, five out of 11 eyes on ICGA, eight out of 11 eyes on SD-OCT, and zero out of 11 eyes on FAF.

CONCLUSION

OCTA images of the superficial and deep retinal plexus, outer retina, and choriocapillaris did not reveal altered flow patterns directly associated with the leakage point in acute CSC. However, OCTA was able to visualize altered choroidal flow in some of the included eyes.

Для цитирования: Feucht Nikolaus, Maier Matthias, Lohmann Chris P, Reznicek Lukas. OCT Angiography Findings in Acute Central Serous Chorioretinopathy.. Ophthalmic surgery, lasers & imaging retina. 2016. DOI: 10.3928/23258160-20160324-03.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.