MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1038/s41598-018-37578-4

Медицинская библиотека · Scientific reports · 2019

Hyperautofluorescent Dots are Characteristic in Ceramide Kinase Like-associated Retinal Degeneration.

Sengillo Jesse D, Cho Galaxy Y, Paavo Maarjaliis, Lee Winston, White Eugenia, Jauregui Ruben, Sparrow Janet R, Allikmets Rando, Tsang Stephen H

СтатьяПоддержка NIH: внешняя программаПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

There is a lack of studies which seek to discern disease expression in patients with mutations that alter retinal ceramide metabolism, specifically in the ceramide kinase like (CERKL) gene. This cross-sectional case series reports a novel phenotypic manifestation of CERKL-associated retinopathy. Four unrelated patients with homozygous CERKL mutations underwent a complete ocular exam, spectral-domain optical coherence tomography, short-wavelength fundus autofluorescence (SW-AF), quantitative autofluorescence (qAF), and full-field electroretinogram (ffERG). Decreased visual acuity and early-onset maculopathy were present in all patients. All four patients had extensive hyperautofluorescent foci surrounding an area of central atrophy on SW-AF imaging, which has not been previously characterized. An abnormal spatial distribution of qAF signal was seen in one patient, and abnormally elevated qAF8 signal in another patient. FfERG recordings showed markedly attenuated rod and cone response in all patients. We conclude that these patients exhibit several features that, collectively, may warrant screening of CERKL as a first candidate: early-onset maculopathy, severe generalized retinal dysfunction, peripheral lacunae, intraretinal pigment migration, and hyperautofluorescent foci on SW-AF.

Для цитирования: Sengillo Jesse D, Cho Galaxy Y, Paavo Maarjaliis, Lee Winston, White Eugenia, Jauregui Ruben, Sparrow Janet R, Allikmets Rando, Tsang Stephen H. Hyperautofluorescent Dots are Characteristic in Ceramide Kinase Like-associated Retinal Degeneration.. Scientific reports. 2019. DOI: 10.1038/s41598-018-37578-4.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.