MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/md.0000000000012578

Медицинская библиотека · Medicine · 2018

99mTc-MIBI single photon emission computed tomography/computed tomography for the incidental detection of rare parathyroid carcinoma.

Chen Zejun, Fu Jingjing, Shao Qing, Zhou Bin, Wang Feng

СтатьяНаблюдательное исследованиеПеревод пока не подготовлен

Аннотация

This study aimed to evaluate the characteristics of parathyroid carcinoma and to validate the diagnostic value of Tc-methoxyisobutylisonitrile (MIBI) single photon emission computed tomography/x-ray computed tomography (SPECT/CT) for differentiating between parathyroid carcinoma and hyperparathyroidism. Four consecutive patients with suspected primary hyperparathyroidism were enrolled in this study and underwent Tc-MIBI SPECT/CT, ultrasonography, enhanced CT, and MRI. Serum parathyroid hormone (PTH) and calcium were measured. All primary and recurrent lesions showed high focal uptake on Tc-MIBI image, whereas metastatic lymph nodes gave false negative results. The serum PTH was 165.14 ± 90.26 pmol/L, which declined rapidly after surgery. One patient with a persistently high PTH (147.5 pmol/L) after surgery presented with multiple lymphadenopathy in the neck. Higher expression of chromogranin A (CgA) further confirmed parathyroid carcinoma as a rare endocrine tumor. Parathyroid carcinoma is thus usually diagnosed incidentally based on nonspecific multiorgan symptoms of hypercalcemia and hyperparathyroidism. Tc-MIBI SPECT/CT may help to localize the parathyroid carcinoma, while MRI is valuable for detecting metastasis. Serum PTH and CgA serve as circulating biomarkers in parathyroid carcinoma, and raised levels of PTH and CgA together with locoregional lymphadenopathy may indicate parathyroid carcinoma. Further studies are needed.

Для цитирования: Chen Zejun, Fu Jingjing, Shao Qing, Zhou Bin, Wang Feng. 99mTc-MIBI single photon emission computed tomography/computed tomography for the incidental detection of rare parathyroid carcinoma.. Medicine. 2018. DOI: 10.1097/md.0000000000012578.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.