MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.surg.2017.10.064

Медицинская библиотека · Surgery · 2018

Sestamibi SPECT/CT versus SPECT only for preoperative localization in primary hyperparathyroidism: a single institution 8-year analysis.

McCoy Kelly L, Ghodadra Anish G, Hiremath Trilochan G, Albarano Angela, Joyce Judith M, Yip Linwah, Carty Sally E, Muthukrishnan Ashok

Сравнительное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Primary hyperparathyroidism is caused by single gland disease in 85% of cases and by multiglandular disease in 15%. Our aim was to discover if the addition of computed tomography acquisition/fusion on a hybrid scanner to traditional dual-phase single-photon emission tomography improves localization accuracy.

METHODS

A prospective database was queried for the perioperative data of patients with sporadic primary hyperparathyroidism who had initial exploration from 2006-2014 with ≥6 month follow-up to define anatomy. Prior to 2010, patients had single-photon emission tomography (n = 633); after 2010, they had single-photon emission tomography/computed tomography (n= 755).

RESULTS

In 1,388 patients, the rates of single gland disease (P=.8), bilateral exploration (P=.4), and negative imaging (145 patients, P=.33) were equal between imaging cohorts. In 1,186 patients with single gland disease, the positive predictive value of single-photon emission tomography/computed tomography was somewhat greater (90% vs 85%) and the accuracy of single-photon emission tomography/computed tomography was superior (83% vs 77%, P=.02). In the 202 patients with multiglandular disease, 20% had negative imaging results with no difference by type (single-photon emission tomography/computed tomography 17%, single-photon emission tomography 23%, P=.3), but single-photon emission tomography/computed tomography was more accurate (36%) than single-photon emission tomography (22%, P=.04) in predicting multiglandular disease.

CONCLUSION

In a large cohort study of patients with sporadic primary hyperparathyroidism undergoing parathyroidectomy, positive single-photon emission tomography/computed tomography results provided more reliable operative guidance than single-photon emission tomography for both single gland disease and multiglandular disease.

Для цитирования: McCoy Kelly L, Ghodadra Anish G, Hiremath Trilochan G, Albarano Angela, Joyce Judith M, Yip Linwah, Carty Sally E, Muthukrishnan Ashok. Sestamibi SPECT/CT versus SPECT only for preoperative localization in primary hyperparathyroidism: a single institution 8-year analysis.. Surgery. 2018. DOI: 10.1016/j.surg.2017.10.064.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.