DOI 10.1111/j.1600-0722.1993.tb01106.x
A modified device for collection and flow-rate measurement of submandibular-sublingual saliva.
Аннотация
The aims of the present study were to measure stimulated submandibular-sublingual (SM-SL) salivary flow rate with a modified Block-Brottman collection device, and, further, to evaluate the reliability of measurements of stimulated SM-SL salivary flow rate by means of this modified Block-Brottman device, as compared to measurements of parotid flow rate using modified Carlson-Crittenden cups. Twenty-nine healthy female volunteers, aged 36 +/- 7 yr, were included. Saliva stimulation was achieved by application of a 3% citric acid solution to the rims of the tongue four times/min, for 3 s every 15 s. On 3 consecutive days, stimulated parotid and SM-SL salivas were collected for 2 min at 07.30, before breakfast (morning value), and at 10.00, 2 h after a standard breakfast (lunchtime values). SM-SL saliva was also collected on one occasion for 2 min x 3. For parotid and SM-SL saliva, the mean stimulated flow rates were in the morning, 1.50 +/- 0.83 and 2.25 +/- 1.12 ml/min, and at lunchtime, 1.71 +/- 1.16 and 2.54 +/- 1.01 ml/min, respectively. For both salivas, lunchtime values were significantly higher than morning values by about 13-14%. Comparing parotid and SM-SL saliva flow rates, we found the SM-SL saliva flow rate to exceed the parotid flow rate by about 50% both in the morning and at lunchtime. Variations in flow rate were analyzed by means of ANOVA. Interindividual variance and variance between measurement days and times of day made up 88% of parotid and 83% of SM-SL total variance.(ABSTRACT TRUNCATED AT 250 WORDS)
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.