MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.talanta.2020.121010

Медицинская библиотека · Talanta · 2020

Dual-emission CdTe quantum dot@ZIF-365 ratiometric fluorescent sensor and application for highly sensitive detection of l-histidine and Cu2.

Wang Xing Ze, Zhang Zi Qing, Guo Rui, Zhang Yi Yun, Zhu Na Jia, Wang Kuo, Sun Ping Ping, Mao Xin Yu, Liu Jun Jie, Huo Jian Zhong, Wang Xin Rui, Ding Bin

СтатьяПеревод пока не подготовлен

Аннотация

l-histidine acts as a semi-essential amino acid, which is medically used in the treatment of gastric ulcer, anemia, allergies. However, the overuse of l-histidine will result in terrible damage to heart disease, slow growth of animals and water pollution in the environment. In addition, Cu2+ pollution is common environmental pollution in the industry. It has the characteristics of high accumulation, migration, and persistence. Given this, through the post-synthesis strategy, CdTe quantum dots (QDs) were the first time to introduce into zeolitic imidazolate framework-ZIF-365 to synthesis dual-emission hybrid material CdTe@ZIF-365 with high quantum yield. TEM mappings and N2 absorption tests are applied to confirm the combination mode between CdTe quantum dots and ZIF-365. It should be noted that CdTe@ZIF-365 can be successfully utilized as a bi-functional ratiometric sensor for highly sensitive discrimination of l-histidine and Cu2+. Firstly, CdTe@ZIF-365 is applied to a fluorescent ratiometric sensor for Cu2+ with high sensitivity (the Ksv value is 2.7417✕107 [M-1]) and selectivity in the mixed cation ions' solution. On the other hand, CdTe@ZIF-365 also behaved as the first example for an excellent ratiometric fluorescent senor for l-histidine with high sensitivity (the Ksv value is 6.0507✕108 [M-1]) and selectivity in the mixed amino acids' solutions.

Для цитирования: Wang Xing Ze, Zhang Zi Qing, Guo Rui, Zhang Yi Yun, Zhu Na Jia, Wang Kuo, Sun Ping Ping, Mao Xin Yu, Liu Jun Jie, Huo Jian Zhong, Wang Xin Rui, Ding Bin. Dual-emission CdTe quantum dot@ZIF-365 ratiometric fluorescent sensor and application for highly sensitive detection of l-histidine and Cu2.. Talanta. 2020. DOI: 10.1016/j.talanta.2020.121010.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.