MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1080/02713683.2016.1238942

Медицинская библиотека · Current eye research · 2016

Changes of Retinal Nerve Fiber Layer Thickness in Obstructive Sleep Apnea Syndrome: A Systematic Review and Meta-analysis.

Wang Wei, He Miao, Huang Wenyong

СтатьяМетаанализСистематический обзорПеревод пока не подготовлен

Аннотация

PURPOSE: Many studies have assessed the changes of retinal nerve fiber layer (RNFL) thickness in patients with obstructive sleep apnea syndrome (OSAS), but the results were inconsistent. Therefore, a meta-analysis was performed to evaluate the RNFL changes in OSAS measured in vivo.

METHODS

Pertinent studies were identified by a comprehensive search of PubMed, Embase, Web of science, Cochrane library, Scopus, and Chinese biomedical disc databases from inception to August 2016. A fixed effects model was used to pool the weighted mean difference (WMD) and 95% confidence interval (CI) between OSAS group and control group.

RESULTS

Seventeen studies were included in the final analysis, with 12 for descriptive analysis and 5 for meta-analysis, involving a total of 1757 eyes (1106 in the OSAS group and 651 in the control group). The RNFL in OSAS was significantly lower than control group, with pooled WMD -3.53 (95%CI: -4.80 to -2.26, P < 0.001) for average RNFL, -3.69 (95%CI:-5.49 to -1.89 P < 0.001) for superior RNFL, -4.66 (95%CI: -6.92 to -2.39, P < 0.001) for inferior RNFL, -3.15 (95%CI:-5.19 to -1.10, P = 0.003) for nasal RNFL, and -2.45 (95%CI: -4.59 to -0.31, P = 0.025) for temporal RNFL. Along with severities of OSAS, a trend of more profound reduction of average RNFL was observed in advanced OSAS, with WMD of average RNFL thickness -1.75 (95%CI:-4.47 to -0.98, P = 0.209) for mild OSAS, -3.54 (95%CI:-6.33 to -0.73, P = 0.013) for moderate OSAS, and -7.17 (95%CI:-10.00 to -4.34, P < 0.001) for severe OSAS. The majority of studies in the descriptive review demonstrated similar findings.

CONCLUSION

The OSAS was associated with a reduced RNFL in all quadrants compared to controls. Evaluation of RNFL may serve as a tool for grading severities of OSAS. Considering the limited evidence, the conclusions should be interpreted cautiously.

Для цитирования: Wang Wei, He Miao, Huang Wenyong. Changes of Retinal Nerve Fiber Layer Thickness in Obstructive Sleep Apnea Syndrome: A Systematic Review and Meta-analysis.. Current eye research. 2016. DOI: 10.1080/02713683.2016.1238942.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.