Bioimpacts of dialyzer variety on phosphorus level in Iranian hemodialysis patients.

Pezeshgi Aiyoub, Moharrami Bahareh, Kolifarhood Goodarz, Sadeghi Alireza, Asadi-Khiavi Masoud

СтатьяПеревод пока не подготовлен

Аннотация

INTRODUCTION

Cardiovascular events are the major cause of death in patients with chronic renal failure. About half of dialysis patients because of reduced phosphorus clearance have hyperphosphatemia. Hyperphosphatemia and following secondary hyperparathyroidism lead to some cardiovascular changes. Hemodialysis (HD) partly removes phosphorus during each dialysis session.

OBJECTIVES

Presented study was designed to evaluate dialyzer variation effect on phosphorus level as a prognostic factor after dialysis using.

MATERIALS AND

METHODS

Six kinds of dialyzer were used for dialysis; low flux (LF) dialyzer (F7 and F8), high flux (HF) dialyzer (F70 and F80) and finally hollow-fiber dialyzers including polyethersulfone (PES) 130 HF and polysulfone (PS) 13 LF. Fifty-seven patients were divided into 6 matched groups included three groups of 10 people and 3 groups of 9 persons in groups: A (F70), B (F80), C (F7), D (F8), E (PES 130 HF) and F (PS 13 LF). Patients were treated for one month with these dialyzers. At the end of the month, blood samples were taken again for phosphorus level before dialysis handling.

RESULTS

The mean pre-dialysis serum phosphorus was 5.03, 5.4, 5.2, 4.6, 4.95 and 5.1 mg/dl and the mean phosphorus was 5.43, 5.01, 4.9, 4.18, 4.17 and 5.3 mg/dl after one month of dialysis, respectively in groups A to F without any statistically differences between pre- and after one month dialysis values respectively.

DISCUSSION: The findings indicate dialyzer type in the control of serum phosphorus has not been effective in the short-term HD. We suggest a study with more duration time.

Для цитирования: Pezeshgi Aiyoub, Moharrami Bahareh, Kolifarhood Goodarz, Sadeghi Alireza, Asadi-Khiavi Masoud. Bioimpacts of dialyzer variety on phosphorus level in Iranian hemodialysis patients.. Journal of renal injury prevention. 2016. DOI: 10.15171/jrip.2016.20.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.