MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.surg.2015.06.047

Медицинская библиотека · Surgery · 2015

Establishing the clinical utility of autofluorescence spectroscopy for parathyroid detection.

McWade Melanie A, Sanders Melinda E, Broome James T, Solórzano Carmen C, Mahadevan-Jansen Anita

СтатьяПоддержка NIH: внешняя программаПоддержка правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND

The inability of surgeons to identify parathyroid glands accurately during cervical endocrine surgery hinders patients from achieving postoperative normocalcemia. An intrinsic, near-infrared fluorescence method was developed for real-time parathyroid identification with high accuracy. This study assesses the clinical utility of this approach.

METHODS

Autofluorescence measurements were obtained from 137 patients (264 parathyroid glands) undergoing parathyroidectomy and/or thyroidectomy. Measurements were correlated to disease state, calcium levels, parathyroid hormone, vitamin D levels, age, sex, ethnicity, and body mass index. Statistical analysis identified which factors affect parathyroid detection.

RESULTS

High parathyroid fluorescence was detected consistently and showed wide variability across patients. Near-infrared fluorescence was used to identify 256 of 264 (97%) of glands correctly. The technique showed high accuracy over a wide variety of disease states, although patients with secondary hyperparathyroidism demonstrated confounding results. Analysis revealed body mass index (P < .01), disease state (P < .01), vitamin D (P < .05), and calcium levels (P < .05) account greatly for variability in signal intensity. Age, sex, parathyroid hormone, and ethnicity had no effect.

CONCLUSION

This intrinsic fluorescence-based intraoperative technique can detect nearly all parathyroid glands accurately in real time. Its discrimination capacity is largely unlimited by patient variables, but several factors affect signal intensity. These results demonstrate potential clinical utility of optical guidance for parathyroid detection.

Для цитирования: McWade Melanie A, Sanders Melinda E, Broome James T, Solórzano Carmen C, Mahadevan-Jansen Anita. Establishing the clinical utility of autofluorescence spectroscopy for parathyroid detection.. Surgery. 2015. DOI: 10.1016/j.surg.2015.06.047.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.