DOI 10.1007/s10554-010-9706-0

Медицинская библиотека · The international journal of cardiovascular imaging · 2010

A comparison of visual and quantitative assessment of left ventricular ejection fraction by cardiac magnetic resonance.

Holloway Cameron J, Edwards Lindsay M, Rider Oliver J, Fast Angela, Clarke Kieran, Francis Jane M, Myerson Saul G, Neubauer Stefan

Сравнительное исследованиеСтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

To determine the accuracy of visual analysis of left ventricular (LV) function in comparison with the accepted quantitative gold standard method, cardiac magnetic resonance (CMR). Cine CMR imaging was performed at 1.5 T on 44 patients with a range of ejection fractions (EF, 5-80%). Clinicians (n = 18) were asked to visually assess EF after sequentially being shown cine images of a four chamber (horizontal long axis; HLA), two chamber (vertical long axis; VLA) and a short axis stack (SAS) and results were compared to a commercially available analysis package. There were strong correlations between visual and quantitative assessment. However, the EF was underestimated in all categories (by 8.4% for HLA, 8.4% for HLA + VLA and 7.9% for HLA + VLA + SAS, P all < 0.01) and particularly underestimated in mild LV impairment (17.4%, P < 0.01), less so for moderate (4.9%) and not for severe impairment (1%). Assessing more than one view of the heart improved visual assessment of LV, EF, however, clinicians underestimated EF by 8.4% on average, with particular inaccuracy in those with mild dysfunction. Given the important clinical information provided by LV assessment, quantitative analysis is recommended for accurate assessment.

Для цитирования: Holloway Cameron J, Edwards Lindsay M, Rider Oliver J, Fast Angela, Clarke Kieran, Francis Jane M, Myerson Saul G, Neubauer Stefan. A comparison of visual and quantitative assessment of left ventricular ejection fraction by cardiac magnetic resonance.. The international journal of cardiovascular imaging. 2010. DOI: 10.1007/s10554-010-9706-0.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.