Artificial organs · 2010

Comparison of perfusion quality in hollow-fiber membrane oxygenators for neonatal extracorporeal life support.

Сравнительное исследованиеСтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Talor Jonathan, Yee Stella, Rider Alan, Kunselman Allen R, Guan Yulong, Undar Akif

Аннотация

Perfusion quality is an important issue in extracorporeal life support (ECLS); without adequate perfusion of the brain and other vital organs, multiorgan dysfunction and other deficits can result. The authors tested three different pediatric oxygenators (Medos Hilite 800 LT, Medtronic Minimax Plus, and Capiox Baby RX) to determine which gives the highest quality of perfusion at flow rates of 400, 600, and 800 mL/min using human blood (36 degrees C, 40% hematocrit) under both nonpulsatile and pulsatile flow conditions. Clinically identical equipment and a pseudo-patient were used to mimic operating conditions during neonatal ECLS. Traditionally, the postoxygenator surplus hemodynamic energy value (SHE(post), extra energy obtained through pulsatile flow) is the one relied upon to give a qualitative determination of the amount of perfusion in the patient; the authors also examined SHE retention through the membrane, as well as the contribution of SHE(post) to the postoxygenator total hemodynamic energy (THE(post)). At each experimental condition, pulsatile flow outperformed nonpulsatile flow for all factors contributing to perfusion quality: the SHE(post) values for pulsatile flow were 4.6-7.6 times greater than for nonpulsatile flow, while the THE(post) remained nearly constant for pulsatile versus nonpulsatile flow. For both pulsatile and nonpulsatile flow, the Capiox Baby RX oxygenator was found to deliver the highest quality of perfusion, while the Minimax Plus oxygenator delivered the least perfusion. It is the authors' recommendation that the Baby RX oxygenator running under pulsatile flow conditions be used for pediatric ECLS, but further studies need to be done in order to establish its effectiveness beyond the FDA-approved time span.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты