MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1167/iovs.06-0727

Медицинская библиотека · Investigative ophthalmology & visual science · 2007

Imaging of birefringent properties of keratoconus corneas by polarization-sensitive optical coherence tomography.

Götzinger Erich, Pircher Michael, Dejaco-Ruhswurm Irene, Kaminski Stephan, Skorpik Christian, Hitzenberger Christoph K

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

PURPOSE: To investigate and map the polarizing properties of keratoconus corneas in vitro and to compare the results with those obtained in normal corneas.

METHODS

Corneal buttons of five keratoconus corneas were investigated by polarization-sensitive optical coherence tomography (PS-OCT). The instrument measures backscattered intensity (conventional OCT), retardation, and (cumulative) slow axis distribution simultaneously. Three-dimensional (3-D) data sets of the polarizing parameters are recorded, and two-dimensional (2-D) cross-sectional images as well as en face images of the distribution of these parameters at the posterior corneal surface are derived. The results are compared to similar maps obtained from normal corneas.

RESULTS

Compared with normal corneas, the retardation and slow axis orientation patterns are heavily distorted in keratoconus corneas. Larger areas of increased and decreased retardation can be found in keratoconus corneas, markedly increased retardation (up to >50 degrees ) can especially be found near the rim of corneal thinning. Contrary to normal corneas, regions where the slow axis markedly changes with depth (by up to 50 degrees -90 degrees ) are observed in keratoconus.

CONCLUSIONS

The observed changes in the cornea's birefringence properties indicate a change in the arrangement of collagen fibrils in the corneal stroma associated with keratoconus. PS-OCT may be a useful tool for the study and diagnosis of corneal disease.

Для цитирования: Götzinger Erich, Pircher Michael, Dejaco-Ruhswurm Irene, Kaminski Stephan, Skorpik Christian, Hitzenberger Christoph K. Imaging of birefringent properties of keratoconus corneas by polarization-sensitive optical coherence tomography.. Investigative ophthalmology & visual science. 2007. DOI: 10.1167/iovs.06-0727.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.