Combined Intacs and posterior chamber toric implantable Collamer lens implantation for keratoconic patients with extreme myopia.

Coskunseven Efekan, Onder Methiye, Kymionis George D, Diakonis Vasilios F, Arslan Ebru, Tsiklis Nikolaos, Bouzoukis Dimitrios I, Pallikaris Ioannis

Клинический случайСтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To evaluate the results of combined Intacs (Addition Technology, Fremont, California, USA) and posterior chamber toric implantable Collamer lens [ICLs] (Visian ICL; STAAR Surgical, Monrovia, California, USA) implantation in keratoconic patients with extreme myopia and irregular astigmatism.

DESIGN

Prospective, single-center, noncomparative, interventional, consecutive case series.

METHODS

Three eyes of two consecutive highly myopic keratoconic patients who had undergone posterior chamber toric ICLs implantation after Intacs implantation. Implantation of posterior chamber toric ICLs was performed at intervals between six and 10 months after Intacs implantation. Uncorrected visual acuity (UCVA), best spectacle-corrected visual acuity (BSCVA), refraction, topographic findings, adverse events, and postoperative complications were noted.

RESULTS

No intraoperative or postoperative complications were observed. An improvement in UCVA and BSCVA was found after the Intacs and toric Visian ICL procedures in all eyes. All eyes were emmetropic within 1 diopter (D), whereas the mean manifest refractive spherical equivalent refraction reduced from -18.50 +/- 2.61 D (range, -16.75 to -21.50 D) to 0.42 D (range, plano to -0.75 D). The mean difference between preoperative and last follow-up UCVA and BSCA was a gain of 6.67 +/- 1.15 lines (range, gain of six to eight lines) and 4.33 +/- 2.52 lines (range, gain of two to seven lines), respectively.

CONCLUSIONS

Combined Intacs and posterior chamber toric phakic Visian ICL implantation in a two-step procedure is an effective method for correcting keratoconic patients with extreme myopia.

Для цитирования: Coskunseven Efekan, Onder Methiye, Kymionis George D, Diakonis Vasilios F, Arslan Ebru, Tsiklis Nikolaos, Bouzoukis Dimitrios I, Pallikaris Ioannis. Combined Intacs and posterior chamber toric implantable Collamer lens implantation for keratoconic patients with extreme myopia.. American journal of ophthalmology. 2007. DOI: 10.1016/j.ajo.2007.05.035.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.