MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.ophtha.2006.11.033

Медицинская библиотека · Ophthalmology · 2007

Intrastromal corneal ring segment implantation by femtosecond laser for keratoconus correction.

Shabayek Mohamed H, Alió Jorge L

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

PURPOSE: To report the outcomes after the implantation of intrastromal corneal ring segments (KERARING) aided by femtosecond laser for the correction of keratoconus.

DESIGN

Prospective consecutive interventional study.

PARTICIPANTS

Twenty-one eyes of 16 consecutive keratoconic patients with mean age 32+/-10.2 years. Forty-five percent were keratoconus grade I, 20% grade II, 15% grade III, and 20% grade IV.

METHODS

Intrastromal corneal ring segments KERARING were implanted for keratoconus correction after corneal tunnel creation with the aid of femtosecond laser (IntraLase Corp, Irvine CA).

MAIN OUTCOME MEASURES: Uncorrected visual acuity (UCVA), best spectacle-corrected visual acuity (BSCVA), refractive outcome, complete ophthalmologic examination, videokeratography, and corneal higher order aberrations (HOA) were determined or performed before and after surgery at 1 day, 1 week, and 3 and 6 months. In addition, operative and postoperative complications were recorded.

RESULTS

KERARING implantation significantly increased UCVA from 0.06 to 0.3 (P< or =0.0001), BSCVA from 0.54 to 0.71 (P< or =0.0003), and decreased the spherical equivalent by 2.28 diopters (D) and the average keratometric values (K value) by 2.24 D (P<0.001). There was no significant difference between the 3 and 6 months follow-up. Forty percent (8 eyes with a relatively low RMS of total HOA) showed a nonsignificant increase in the RMS of total HOA and 60% (12 eyes with a relatively higher RMS of total HOA> or =3.0 microm) showed significant (P< or =0.01) decrease in the RMS of total HOA due to a significant (P< or =0.003) reduction in coma and comalike aberrations. The amount of change in corneal curvature (biomechanical response) ranged from a decrease of 18% from its initial value to an increase of 2.75% and was not correlated to any preoperative parameter. Localized infectious keratitis occurred in only 1 eye (4.8%), and incision opacification occurred in 8 eyes (38%).

CONCLUSION

Intrastromal corneal ring segment implantation with femtosecond laser is an effective method for correcting keratoconus with reduction in corneal HOA in eyes with coma aberration > 3.0 microm.

Для цитирования: Shabayek Mohamed H, Alió Jorge L. Intrastromal corneal ring segment implantation by femtosecond laser for keratoconus correction.. Ophthalmology. 2007. DOI: 10.1016/j.ophtha.2006.11.033.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.