Penetrating keratoplasty versus intrastromal corneal ring segments to correct bilateral corneal ectasia: preliminary study.

Rodríguez Luis A, Guillén Pamela B, Benavides María A, Garcia Licette, Porras Dianela, Daqui-Garay Rodrigo M

Сравнительное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To describe the outcomes over time in patients with corneal ectasia pathology treated with intrastromal corneal ring segments (Intacs, Addition Technology, Inc.) in 1 eye and penetrating keratoplasty (PKP) in the other eye.

SETTING

Clinica de Cornea, Centro Medico Docente La Trinidad, Caracas, Venezuela.

METHODS

A nonrandomized comparative study and analysis of retrospective data comprised 17 patients who had PKP in 1 eye and Intacs implantation in the other eye. Patients were classified into 2 groups: asymmetric (different grade of keratoconus in each eye) and symmetric (same grade of keratoconus in both eyes). Parameters analyzed included uncorrected visual acuity (UCVA), best corrected visual acuity (BCVA), and keratometry (flat and steep values and astigmatism readings). Follow-up after PKP was at 24 hours and 6 and 24 months and after Intacs implantation, at 24 hours and 3 and 10 months.

RESULTS

In both groups, UCVA improved and the corneal shape was normal. No patient lost a line of acuity, and BCVA improved in both groups.

CONCLUSIONS

Eyes with Intacs had a shorter recovery time than eyes having PKP. The eyes with Intacs had no complications. Complications in eyes with PKP included cataract, graft rejection, and elevated intraocular pressure. Thus, Intacs segments may delay or prevent the need for a corneal graft, although longer follow-up is needed.

Для цитирования: Rodríguez Luis A, Guillén Pamela B, Benavides María A, Garcia Licette, Porras Dianela, Daqui-Garay Rodrigo M. Penetrating keratoplasty versus intrastromal corneal ring segments to correct bilateral corneal ectasia: preliminary study.. Journal of cataract and refractive surgery. 2007. DOI: 10.1016/j.jcrs.2006.09.048.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.