DOI 10.1016/j.jcrs.2006.02.044
Intracorneal ring segments for keratoconus correction: long-term follow-up.
Аннотация
PURPOSE: To evaluate long-term results and stability of intracorneal ring segment (Intacs) implantation for keratoconus correction.
SETTING
Vissum, Instituto Oftalmológico de Alicante and University of Miguel Hernandez, Alicante, Spain.
METHODS
This retrospective study comprised 13 eyes operated on between April 2000 and December 2001 that had Intacs implantation for keratoconus correction. The outcomes were evaluated at 6, 12, 24, and 36 months in all eyes and at 48 months (6 eyes).
RESULTS
Mean best spectacle-corrected visual acuity (BSCVA) increased from 0.46 (20/50) preoperatively to 0.66 (20/30) postoperatively (P< or =.001). Mean decrease of inferior-superior (I-S) asymmetry was 2.81 diopters (D) (P< or =.02), and the average K-value was 3.13 D (P< or =.001). Mean difference between 6 and 36 months (stability) showed no significant difference regarding BSCVA (P< or =.5) and I-S asymmetry (P< or =.6). Although a significant increase was noticed in the average K by 1.67 D (P< or =.002), at 36 months it did not reach the initial preoperative values.
CONCLUSION
Intacs increased the BSCVA and decreased I-S asymmetry with stability up to 36 months. In spite of the decrease of the K-values at 6 months, a further significant increase was detected 36 months after surgery.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.