MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jcrs.2006.02.012

Медицинская библиотека · Journal of cataract and refractive surgery · 2006

Analysis of results related to good and bad outcomes of Intacs implantation for keratoconus correction.

Alió Jorge L, Shabayek Mohamed H, Belda José I, Correas Pablo, Feijoo Elio Diez

Сравнительное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To evaluate factors influencing good and poor outcomes after intracorneal ring segment implantation to correct keratoconus.

SETTING

Instituto Oftalmológico de Alicante (Vissum Corporation), University of Miguel Hernandez, Alicante, Spain.

METHODS

A retrospective comparative study of the visual outcome, 25 eyes of 21 patients were implanted after intracorneal ring segments (Intacs, Addition Technology) as a method to correct keratoconus. Outcomes were evaluated 6 months after implantation based on the visual results. Group A comprised 20 eyes that gained 3 lines or more of best spectacle-corrected visual acuity (BSCVA) to correct keratoconus, and Group B comprised 5 eyes that lost 1 line of BSCVA.

RESULTS

In Group A, the preoperative mean BSCVA was 0.43 (20/50) and the postoperative mean BSCVA, 0.82 (20/20) (P< or =.0001). In Group B, the preoperative mean BSCVA was 0.36 (20/63) and the postoperative mean BSCVA, 0.24 (20/80) (P< or =.02). The preoperative mean sphere power was 3.90 diopters (D) greater in Group B than in Group A (P< or =.007); the mean spherical equivalent was 4.36 D greater (P< or =.007), and the mean K-reading was 6.91 D greater (P< or =.001). The postoperative reduction in spherical dioptric power was 2.11 D (P< or =.027) and the mean spherical equivalent, 2.81 D (P< or =.003), significant only in Group A. The reduction in mean central K-readings was 4.30 D (P< or =.0001) in Group A and 6.19 D (P< or =.014) in Group B. The correlation of the preoperative mean K value to the postoperative BSCVA was significant at the .01 level by the Pearson test (-0.67). In Group A, all eyes (100%) had a mean K-reading < or =53 D. In Group B, 4 eyes (80%) had a mean K-reading > or =55 D.

CONCLUSION

Intacs provided better results in visual acuity and corneal topography quality and significantly reduced the spherical equivalent in eyes with keratoconus with relatively low mean K values (< or =53 D) and a relatively low spherical equivalent. In advanced keratoconus (mean K-reading > or =55 D), poor results can be anticipated.

Для цитирования: Alió Jorge L, Shabayek Mohamed H, Belda José I, Correas Pablo, Feijoo Elio Diez. Analysis of results related to good and bad outcomes of Intacs implantation for keratoconus correction.. Journal of cataract and refractive surgery. 2006. DOI: 10.1016/j.jcrs.2006.02.012.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.