Аннотация

PURPOSE: The purpose of this article is to compare the safety and efficacy of flat- and steep-fitting rigid contact lenses in keratoconus.

METHODS

The Collaborative Longitudinal Evaluation of Keratoconus (CLEK) Study is a 16-center observational study. Cross-sectional results at baseline were generated for 1091 subjects with longitudinal results from the 871 subjects who completed 8 years of follow up.

RESULTS

Of the 761 rigid contact lens-wearing patients at baseline, 41% had a scar at baseline compared with 24% of the nonrigid contact lens wearers (odds ratio [OR], 2.15; 95% confidence interval [CI], 1.35-3.43; p = 0.001). Eighty-seven percent were fitted with flat-fitting lenses, whereas 13% were fitted with steep-fitting lenses. Rigid lens fitting method was also associated with incident corneal scarring. A greater proportion of the corneas wearing flat-fitting contact lenses were scarred (43% compared with 26% for the steep-fitted eyes; OR,= 2.19; 95% CI, 1.37-3.51; p = 0.001). After controlling for corneal curvature, the association of rigid contact lens fit and corneal scarring at baseline did not persist (adjusted OR, 1.20; 95% CI, 0.70-2.06; p = 0.52). Thirty-two percent of unscarred eyes at baseline fitted flat had developed an incident corneal scar by the eighth year follow-up visit compared with 14% of eyes fitted steep (OR, 2.93; 95% CI, 1.34-6.42; p = 0.007).

CONCLUSIONS

The data reported here indicate that, after controlling for disease severity in the form of corneal curvature, keratoconic eyes fitted with a rigid contact lens resulting in an apical touch fluorescein pattern did not have an increased risk of being scarred centrally at baseline. This "natural history" sample cannot determine causal proof that one method of fitting lenses is safer than another. To achieve this, a randomized clinical trial is needed.

Для цитирования: Zadnik Karla, Barr Joseph T, Steger-May Karen, Edrington Timothy B, McMahon Timothy T, Gordon Mae O, Collaborative Longitudinal Evaluation of Keratoconus (CLEK) Study Group. Comparison of flat and steep rigid contact lens fitting methods in keratoconus.. Optometry and vision science : official publication of the American Academy of Optometry. 2005. DOI: 10.1097/01.opx.0000192349.11525.de.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.