MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1136/bjo.2005.069500

Медицинская библиотека · The British journal of ophthalmology · 2005

Contact lenses and special back surface design after penetrating keratoplasty to improve contact lens fit and visual outcome.

Gruenauer-Kloevekorn C, Kloevekorn-Fischer U, Duncker G I W

Оценочное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

AIMS: To describe the fitting of patients with high or irregular astigmatism following penetrating keratoplasty with contact lenses and to answer the question whether or not contact lenses with special back surface design can improve visual acuity in complex cases after penetrating keratoplasty.

METHODS

28 eyes were included. They were fitted with contact lenses with a special back surface that was designed for optical rehabilitation after penetrating keratoplasty. Four different types of these lenses (tricurve, keratoconus, reverse, oblong) were used selectively depending on abnormal eccentricity determined by videokeratoscope. The patients were followed up for an average period of 15.5 months. Lens tolerance and corrected visual acuity were evaluated and compared with that corrected with spectacles.

RESULTS

The visual acuity was significantly improved in nearly all eyes with an average increase of 3.6 lines (maximal nine lines) accompanied by good contact lens tolerance and satisfactory contact lens fit. No noticeable complications were observed.

CONCLUSION

Contact lenses with special back surface design can improve visual results and lens tolerance, and minimise problems in contact lens fitting. This is in favour of contact lenses as an alternative to surgical procedures for correction of high or irregular astigmatism after penetrating keratoplasty. This procedure is recommended especially in cases of patients who decline further operative interventions.

Для цитирования: Gruenauer-Kloevekorn C, Kloevekorn-Fischer U, Duncker G I W. Contact lenses and special back surface design after penetrating keratoplasty to improve contact lens fit and visual outcome.. The British journal of ophthalmology. 2005. DOI: 10.1136/bjo.2005.069500.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.