Sethi Rishi, Pradhan Akshyaya, Vishwakarma Pravesh, Hazra Prakash Kumar, Chatterjee Sumanta, Kundu Supratip, Bhowmik Pradip, Choudhury Parijat Deb, Shamraj Pranav, Bhandari Monika, Kasturi Sridhar, Reddy Shanivaram Vijay Kumar, George Sheeba, Sharma Yash Paul, Panda Prashant Kumar, Potdar Anil, Patnaik Ravi Kumar

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Recent advances in percutaneous coronary interventions (PCIs) have substantially improved clinical outcomes. Generating real-world evidence on the 1-year outcomes of ultrathin-strut drug-eluting stents (DES) remains important, particularly in healthcare settings where cost and accessibility may influence stent selection.

METHODS

A prospective, single-arm, multicenter registry was conducted to evaluate the 1-year safety and efficacy of an indigenous everolimus-eluting cobalt-chromium stent (EES) (Pristine+™ - Make: Relisys Medical Devices Limited, India) featuring an ultrathin strut (60-µm) design. The primary endpoint was the 1-year incidence of major adverse cardiac event (MACE) defined as a composite of cardiac death (CD), myocardial infarction (MI), and stent thrombosis (ST).

RESULTS

The study enrolled 1,088 patients, predominantly male (78.9%). High prevalence of diabetes mellitus (34.7%), hypertension (63.9%), and smoking history (25.7%) was noted. The mean age was 58.6 ± 10.6 years, with 69.9% between 36 and 65 years. A total of 95.9% completed the 1-year follow-up. At 1-year, the Kaplan-Meier incidence of MACE was 2.89% (40 events), comprising 18 CD (1.65%), 13 MI (1.19%), and nine ST (0.83%). All-cause mortality was 2.3% (25 events). One target-vessel myocardial infarction (TV-MI; 0.09%) was reported and no clinically indicated target-lesion revascularization (CI-TLR) events occurred.

CONCLUSION

This study demonstrated favorable 1-year clinical outcomes with Pristine+™, reflected by low rates of MACE and no CI-TLR during the 1-year follow-up. A total of 1,386 Pristine+ EES were implanted in this study.

Для цитирования: Sethi Rishi, Pradhan Akshyaya, Vishwakarma Pravesh, Hazra Prakash Kumar, Chatterjee Sumanta, Kundu Supratip, Bhowmik Pradip, Choudhury Parijat Deb, Shamraj Pranav, Bhandari Monika, Kasturi Sridhar, Reddy Shanivaram Vijay Kumar, George Sheeba, Sharma Yash Paul, Panda Prashant Kumar, Potdar Anil, Patnaik Ravi Kumar. Pristine+™ Everolimus-Eluting Cobalt-Chromium Coronary Stent System: A Prospective, Multicenter Registry.. Cardiology research. 2026. DOI: 10.14740/cr2230.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.