99mTc-methionine scintimammography in the evaluation of breast cancer.

Sharma Rajnish, Tripathi Madhavi, Panwar Puja, Chuttani Krishna, Jaimini Abhinav, Maitra Sudeshna, Chopra Mahinder Kumar, Sawroop Krishan, Shukla Gauri, Mondal Anupam, Mishra Anil

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVE

The diagnostic utility of a C-methionine scan has been established in breast cancer. We were able to radiolabel methionine with Tc at our institute. Thus, we undertook clinical trials to determine the role of Tc-methionine scans in the detection of breast cancer.

METHODS

Scintimammography was performed in 47 female (median age 44 years, range 28-68 years) patients having palpable breast masses. All of them underwent ultrasound, mammography, fine-needle aspiration cytology, and Tc-methionine scintimammography before surgery. The final diagnosis was made after histopathological examination. Tc-methionine scintimammography was done after injecting 555 MBq of radiotracer intravenously. The results of scintimammography were compared with histopathology.

RESULTS

The histopathological findings were malignant in 33 (70%) and benign in 14 (30%) cases. Scintimammography showed true-positive findings in 29 patients out of 33 cases of breast cancer. True-negative findings were found in 13 out of 14 patients having benign breast lesions. The sensitivity, specificity, and positive predictive value were found to be 87.8, 92.8, and 96.6% respectively.

CONCLUSION

Tc-methionine imaging can provide useful information with reasonably high sensitivity and specificity in evaluating patients having breast masses.

Для цитирования: Sharma Rajnish, Tripathi Madhavi, Panwar Puja, Chuttani Krishna, Jaimini Abhinav, Maitra Sudeshna, Chopra Mahinder Kumar, Sawroop Krishan, Shukla Gauri, Mondal Anupam, Mishra Anil. 99mTc-methionine scintimammography in the evaluation of breast cancer.. Nuclear medicine communications. 2009. DOI: 10.1097/mnm.0b013e32832999dc.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.