DOI 10.1097/ico.0000000000002148

Медицинская библиотека · Cornea · 2020

Efficacy of the Fluorescein Tear Breakup Time Test in Dry Eye.

Paugh Jerry R, Tse June, Nguyen Tiffany, Sasai Alan, Chen Elaine, De Jesus Melinda Thomas, Kwan Justin, Nguyen Andrew Loc, Farid Marjan, Garg Sumit, Jester James V

СтатьяРандомизированное исследованиеПеревод пока не подготовлен

Аннотация

PURPOSE: To examine the effects of volume and method on fluorescein tear breakup time (TBUT) values and to evaluate test efficacy in an independent sample free of selection bias.

METHODS

Subjects were assessed using a battery of dry eye tests (DETs). Efficacy study: Subjects were randomized to the DET, standard strip, and liquid NaFl on separate days. A masked examiner measured TBUTs from video recordings. Verification study: Subjects were investigated for efficacy using volumes of 5.0 and 2.0 μL mL of NaFl for TBUT.

RESULTS

Efficacy study: 46 subjects completed the study. Log-transformed TBUTs were significantly different, normal subjects versus dry subjects, for all 3 methods (all P values < 0.001). Area under the curves (AUCs), cut-points, sensitivity, and specificity were 1) DET: 0.873, 4.4 seconds, 0.97, and 0.67, respectively; 2) 2.0 mL: 0.901, 3.22 seconds, 0.90, and 0.87, respectively; and 3) standard strip: 0.912, 3.42 seconds, 0.97, and 0.80, respectively. Verification study: Data splitting analysis for the 2.0 μL data (n = 174 dry subjects and 97 normal subjects) generated an AUC of 0.917 and a cut-point of 6.05 seconds for a sensitivity of 0.87 and a specificity of 0.81. The 5.0 μL sample yielded an AUC of 0.940, with a sensitivity and specificity of 0.92 and 0.83, respectively, at a cut-point of 5.5 seconds.

CONCLUSIONS

Little difference in TBUT was found using the 3 clinical methods with video recordings. Analysis using liquid NaFl suggests that the TBUT test has excellent diagnostic accuracy and that a cut-point of 5.3 to 6.0 seconds is the optimum to differentiate normals from persons with dry eye.

Для цитирования: Paugh Jerry R, Tse June, Nguyen Tiffany, Sasai Alan, Chen Elaine, De Jesus Melinda Thomas, Kwan Justin, Nguyen Andrew Loc, Farid Marjan, Garg Sumit, Jester James V. Efficacy of the Fluorescein Tear Breakup Time Test in Dry Eye.. Cornea. 2020. DOI: 10.1097/ico.0000000000002148.