MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3988/jcn.2020.16.4.586

Медицинская библиотека · Journal of clinical neurology (Seoul, Korea) · 2020

Reliability and Validity of the Korean Version of the Spinal and Bulbar Muscular Atrophy Functional Rating Scale.

Oh Seong Il, Oh Juyeon, Park Donghwi, Son Kwangjoo, Park Jin Sung

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND AND PURPOSE: The Spinal and Bulbar Muscular Atrophy Functional Rating Scale (SBMAFRS) is a reliable and valid instrument for evaluating the functional status of patients with spinal and bulbar muscular atrophy (SBMA). This study aimed to validate a Korean version of the SBMAFRS in an SBMA population.

METHODS

We applied the SBMAFRS to 64 SBMA patients at their regular follow-up clinical visits. The patients underwent clinical evaluations that included the 6-minute walking test (6MWT), forced vital capacity (FVC), manual muscle test, and the Penetration-Aspiration Scale (PAS). To estimate the stability of the SBMAFRS, the scale was reapplied to a subset of 31 randomly selected patients within 4 weeks of the initial test. The convergent validity was evaluated, and correlations were examined between SBMAFRS items and the muscular force, the total and subscores on the Revised Amyotrophic Lateral Sclerosis Functional Rating Scale (ALSFRS-R), FVC, PAS score, age at onset, disease duration, and 6MWT results.

RESULTS

The internal consistency of the scale was confirmed by a high Cronbach's alpha (total raw alpha=0.867, total standardized alpha=0.863). The test-retest reliability as assessed by Spearman's rho was also high. The total score and subscores of the SBMAFRS were strongly correlated with the respective items and subscores of the ALSFRS-R, respiratory function, and the 6MWT.

CONCLUSIONS

We have performed a validation study of the Korean version of a disease-specific functional rating scale for SBMA patients. The SBMAFRS is a useful tool for clinical practice and as a potential outcome measure for Korean SBMA patients.

Для цитирования: Oh Seong Il, Oh Juyeon, Park Donghwi, Son Kwangjoo, Park Jin Sung. Reliability and Validity of the Korean Version of the Spinal and Bulbar Muscular Atrophy Functional Rating Scale.. Journal of clinical neurology (Seoul, Korea). 2020. DOI: 10.3988/jcn.2020.16.4.586.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.