Right anterior mini-thoracotomy for isolated aortic valve replacement: An international and multicenter study.

Fatehi Hassanabad Ali, Fatehi Hassanabad Mortaza, King Melissa A, McKenzie Madeleine P, Bergeron Alexandre, Manerikar Adwaiy, Huskin Anna, Kruse Jane, Baldridge Abigail S, Fercho Justyna, Janeczek Mateusz, Israr-Ul-Haq Muhammad, Rheault-Henry Mathieu, Dan Abdullatif Abo, Chu Michael W A, Ahsan Muhammad R, Smith Holly N, Maitland Andrew, Holloway Daniel D, Karolak Wojtek, Malaisrie S Christopher, Bouchard Denis, Adams Corey, Kent William D T

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Right anterior mini thoracotomy (RAMT) is a sternum-sparing approach for aortic valve replacement (AVR). Single-center studies have found RAMT AVR to be safe; however, there is a paucity of large, multicenter, all-comer, and real-world data for this surgical strategy.

METHODS

This retrospective study investigated the outcomes of isolated RAMT AVR at 6 centers in the United States, Canada, and Europe. Primary outcomes were death and disabling stroke within 30 days of surgery. Secondary outcomes included rate of conversion to sternotomy, prosthetic used, operative times, residual paravalvular leak, rate of permanent pacemaker (PPM) implantation, incidence of new onset postoperative atrial fibrillation (POAF), rate of blood transfusion, and intensive care unit and hospital length of stay.

RESULTS

Seven hundred and sixteen patients underwent isolated RAMT AVR between January 2012 and December 2024 across 6 centers. Four hundred and twenty-eight were male, and the mean age of the cohort was 68.1 ± 10.7 years. Six patients (0.8%) died and 3 (0.4%) experienced a disabling stroke. Thirteen patients (1.8%) required emergent reoperation to control bleeding, while 45 (6.3%) received transfused blood products. One hundred and thirty patients (18.2%) experienced POAF. The incidence of permanent pacemaker implantation after a sutured valve replacement was 2.51% (n = 18 patients). The median intensive care unit and hospital length of stay was 1 day and 5 days, respectively.

CONCLUSIONS

The findings of this study, the largest multicenter study on RAMT AVR reported to date, suggest that this is a safe operation associated with excellent outcomes.

Для цитирования: Fatehi Hassanabad Ali, Fatehi Hassanabad Mortaza, King Melissa A, McKenzie Madeleine P, Bergeron Alexandre, Manerikar Adwaiy, Huskin Anna, Kruse Jane, Baldridge Abigail S, Fercho Justyna, Janeczek Mateusz, Israr-Ul-Haq Muhammad, Rheault-Henry Mathieu, Dan Abdullatif Abo, Chu Michael W A, Ahsan Muhammad R, Smith Holly N, Maitland Andrew, Holloway Daniel D, Karolak Wojtek, Malaisrie S Christopher, Bouchard Denis, Adams Corey, Kent William D T. Right anterior mini-thoracotomy for isolated aortic valve replacement: An international and multicenter study.. JTCVS open. 2025. DOI: 10.1016/j.xjon.2025.101553.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.