Evaluation of the CareStart™ glucose-6-phosphate dehydrogenase (G6PD) rapid diagnostic test in the field settings and assessment of perceived risk from primaquine at the community level in Cambodia.

Wojnarski Bertha, Lon Chanthap, Sea Darapiseth, Sok Somethy, Sriwichai Sabaithip, Chann Soklyda, Hom Sohei, Boonchan Threechada, Ly Sokna, Sok Chandara, Nou Samon, Oung Pheaktra, Kong Nareth, Pheap Vannak, Thay Khengheang, Dao Vy, Kuntawunginn Worachet, Feldman Mitra, Gosi Panita, Buathong Nillawan, Ittiverakul Mali, Uthaimongkol Nichapat, Huy Rekol, Spring Michele, Lek Dysoley, Smith Philip, Fukuda Mark M, Wojnarski Mariusz

Оценочное исследованиеСтатьяПоддержка правительства СШАПеревод в очереди

Аннотация

BACKGROUND

Primaquine is an approved radical cure treatment for Plasmodium vivax malaria but treatment can result in life-threatening hemolysis if given to a glucose-6-phosphate dehydrogenase deficient (G6PDd) patient. There is a need for reliable point-of-care G6PD diagnostic tests.

OBJECTIVES

To evaluate the performance of the CareStart™ rapid diagnostic test (RDT) in the hands of healthcare workers (HCWs) and village malaria workers (VMWs) in field settings, and to better understand user perceptions about the risks and benefits of PQ treatment guided by RDT results.

METHODS

This study enrolled 105 HCWs and VMWs, herein referred to as trainees, who tested 1,543 healthy adult male volunteers from 84 villages in Cambodia. The trainees were instructed on G6PD screening, primaquine case management, and completed pre and post-training questionnaires. Each trainee tested up to 16 volunteers in the field under observation by the study staff.

RESULTS

Out of 1,542 evaluable G6PD volunteers, 251 (16.28%) had quantitative enzymatic activity less than 30% of an adjusted male median (8.30 U/g Hb). There was no significant difference in test sensitivity in detecting G6PDd between trainees (97.21%), expert study staff in the field (98.01%), and in a laboratory setting (95.62%) (p = 0.229); however, test specificity was different for trainees (96.62%), expert study staff in the field (98.14%), and experts in the laboratory (98.99%) (p < 0.001). Negative predictive values were not statistically different for trainees, expert staff, and laboratory testing: 99.44%, 99.61%, and 99.15%, respectively. Knowledge scores increased significantly post-training, with 98.7% willing to prescribe primaquine for P.vivax malaria, an improvement from 40.6% pre-training (p < 0.001).

CONCLUSION

This study demonstrated ability of medical staff with different background to accurately use CareStart™ RDT to identify G6PDd in male patients, which may enable safer prescribing of primaquine; however, pharmacovigilance is required to address possible G6PDd misclassifications.

Для цитирования: Wojnarski Bertha, Lon Chanthap, Sea Darapiseth, Sok Somethy, Sriwichai Sabaithip, Chann Soklyda, Hom Sohei, Boonchan Threechada, Ly Sokna, Sok Chandara, Nou Samon, Oung Pheaktra, Kong Nareth, Pheap Vannak, Thay Khengheang, Dao Vy, Kuntawunginn Worachet, Feldman Mitra, Gosi Panita, Buathong Nillawan, Ittiverakul Mali, Uthaimongkol Nichapat, Huy Rekol, Spring Michele, Lek Dysoley, Smith Philip, Fukuda Mark M, Wojnarski Mariusz. Evaluation of the CareStart™ glucose-6-phosphate dehydrogenase (G6PD) rapid diagnostic test in the field settings and assessment of perceived risk from primaquine at the community level in Cambodia.. PloS one. 2020. DOI: 10.1371/journal.pone.0228207.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.