m+Medelevator.RU
← Поиск публикаций
Graefe's archive for clinical and experimental ophthalmology = Albrecht von Graefes Archiv fur klinische und experimentelle Ophthalmologie · 2022

Corneal stromal dehydration and optimal stromal exposure time during corneal refractive surgery measured using a three-dimensional optical profiler.

СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Wu Yanan, Wang Yan, Zhang Zimiao, Yu Xingchen

Аннотация

PURPOSE: To quantitatively analyze human corneal stromal dehydration and estimate proper corneal stromal exposure time during corneal refractive surgery.

METHODS: The central thickness changes over time in 34 pieces of human corneal tissue were measured using a white light interferometer. The corneal stromal tissue was obtained by femtosecond laser small incision lenticule extraction. The thickness-time dehydration fitting curves were drawn, and the determination coefficient R2 was calculated. The differences in the fitting curve equation coefficients were compared between the thin and thick lenticule groups. The optimal stromal exposure time was calculated under various conditions, including different optical zones and allowable refractive errors.

RESULTS: A water loss variation model was successfully established. Linear and quadratic fitting curves were drawn, and the determination coefficient R2 values were significantly close to 1. The average values of R2 for quadratic curves and linear phases 1, 2, and 3 were 0.998 ± 0.002, 0.995 ± 0.007, 0.996 ± 0.003, and 0.984 ± 0.035, respectively. The optimal stromal exposure time varied under different optical zones and allowable diopter error conditions. Taking the allowable error of 0.50 D and the optical zone size of 6.5 mm as an example, the optimal time was approximately 24 s.

CONCLUSIONS: The dehydration rate of the human corneal stroma is nonlinear, and the quadratic stromal thickness-time dehydration fitting curve is more in line with the actual water loss trend. The length of the stroma exposure time may affect the postoperative refractive accuracy after corneal refractive surgery.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты