MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3390/medicina61010013

Медицинская библиотека · Medicina (Kaunas, Lithuania) · 2024

Using the Cardiac-Electrophysiological Balance Index to Predict Arrhythmia Risk After Colonoscopy.

Polatkan Seyit Ali Volkan, Gunay-Polatkan Seyda, Isik Ozgen, Sigirli Deniz

СтатьяПеревод пока не подготовлен

Аннотация

Background and

Objectives

Colorectal cancer is the second leading cause of cancer-related deaths in the U.S., and colonoscopy is a critical tool for colon cancer screening and diagnosis. Electrolyte disturbances and autonomic nervous system dysfunction that may occur due to bowel preparation and the colonoscopy procedure itself may play a role in the development of cardiac arrhythmia. This study aimed to assess the index of cardiac-electrophysiological balance (iCEB) to predict ventricular arrhythmia risk related to colonoscopy. Materials and

Methods

Patients undergoing elective colonoscopy with a normal sinus rhythm were included. Electrocardiography (ECG) recordings both before bowel preparation and after the colonoscopy procedure were obtained. Values of the index of cardiac-electrophysiological balance (iCEB) were compared.

Results

Among 36 patients, it was determined that the heart rate values of the patients before bowel preparation were higher than the heart rate values after colonoscopy [74.5 (60-108) bpm vs. 68.5 (53-108) bpm, p = 0.021]. The duration of QT interval increased (370.9 ± 27.8 ms vs. 398.7 ± 29.4 ms, p < 0.001) and the iCEB increased from 4.1 ± 0.5 to 4.5 ± 0.6 (p < 0.001), indicating a significant post-procedural risk of ventricular arrhythmias.

Conclusions

These findings suggest that routine iCEB assessment post-colonoscopy could identify high-risk patients requiring closer monitoring.

Для цитирования: Polatkan Seyit Ali Volkan, Gunay-Polatkan Seyda, Isik Ozgen, Sigirli Deniz. Using the Cardiac-Electrophysiological Balance Index to Predict Arrhythmia Risk After Colonoscopy.. Medicina (Kaunas, Lithuania). 2024. DOI: 10.3390/medicina61010013.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.