DOI 10.1016/j.jcrs.2010.11.032
Dissatisfaction after implantation of multifocal intraocular lenses.
Аннотация
PURPOSE: To analyze the symptoms, etiology, and treatment of patient dissatisfaction after multifocal intraocular lens (IOL) implantation.
SETTING
Department of Ophthalmology, Maastricht University Medical Center, The Netherlands.
DESIGN
Case series.
METHODS
In this retrospective chart review, the main outcome measures were type of complaints, uncorrected and corrected distance visual acuities, uncorrected and distance-corrected near visual acuities, refractive state, pupil diameter and wavefront aberrometry measurements, and type of treatment.
RESULTS
Seventy-six eyes of 49 patients were included. Blurred vision (with or without photic phenomenon) was reported in 72 eyes (94.7%) and photic phenomena (with or without blurred vision) in 29 eyes (38.2%). Both symptoms were present in 25 eyes (32.9%). Residual ametropia and astigmatism, posterior capsule opacification, and a large pupil were the 3 most significant etiologies. Sixty-four eyes (84.2%) were amenable to therapy, with refractive surgery, spectacles, and laser capsulotomy the most frequent treatment modalities. Intraocular lens exchange was performed in 3 cases (4.0%).
CONCLUSION
The cause of dissatisfaction after implantation of a multifocal IOL can be identified and effective treatment measures taken in most cases.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.